NEVER LEAVE HEATER UNATTENDED WHILE BURNING,

CONNECTED TO A POWER SOURCE, OR WHILE

CONNECTED TO A FUEL SOURCE

© 2014, Pinnacle Products International, Inc.

Convection Heater User's Manual

®

Problem

Possible Cause

Solution

Burner fails to ignite

1. Valve on supply cylinder

closed.

2. Cylinder excess flow check

valve closed.

3. Burner nozzle blockage.

4. Ignition system not sparking.

1. Open cylinder valve.

2. Close cylinder valve,wait

one minute, and re-open

slowly.

3. Replace Burner Nozzle.

4. Inspect igniter wires for

damage, be sure spark gap

is .195”.

Burner lights, but the flame goes

out when Control Knob is turned

to desired setting

1. Not enough time for

thermocouple to warm up.

2. Gas pressure too low.

3. Thermocouple needs

replacing, or loose.

4. Control valve damaged.

1. Keep Control Valve

depressed for at least 30

seconds.

2. Check cylinders for

adequate gas.

3. Replace or tighten

thermocouple connection.

4. Replace Control Valve.

Burner flame is too low

1. Cylinder valve not fully

open.

2. Clogged burner orifice.

3. Gas pressure too low.

4. Fuel supply too low.

1. Be sure cylinder valve is

fully opened.

2. Replace burner.

3. Be sure regulator is

operating properly.

4. Replace low fuel supply with

new, full cylinder.

Troubleshooting Guide

Locating Your Serial Number:

Your serial number can be found on the heater’s rating label. It will begin with the letters HCV

followed by 8 digits. For Example: HCV12345678. Have your Serial Number ready before calling

customer service at 800-641-6996.