2shudwlrq, Xholqj7kh+hdwhu, 9hqwlodwlrq – ProTemp PT-215T-KFA User Manual
Page 8: Ohfwulfdo2xwohw

NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
© 2013, Pinnacle Products International, Inc.
Kerosene Forced Air Heater User’s Manual
®
2SHUDWLRQ
)XHOLQJ7KH+HDWHU
Kerosene (1-K)
For optimal performance of this heater, it is
strongly suggested that 1-K kerosene be used.
.NHURVHQHKDVEHHQUH¿QHGWRYLUWXDOO\
eliminate contaminants, such as sulfur, which can
cause a rotten egg odor during the operation of
the heater. Using diesel fuel can cause excess
soot production. Do not use Bio-Diesel as this
IXHOZLOOGDPDJH\RXUKHDWHU¶VVHDOVDQG¿OWHU
&6$FHUWLILHGIRUXVHZLWK.NHURVHQH
QR QRGLHVHO-3-HW$)XHO
QRDQGQRIXHORLO
DO NOT use any fuel that is not approved above.
- NEVER use fuel such as, benzene, alcohol, white
glass, camp stove fuel, paint thinners, or other oil
compounds in this heater. THESE ARE VOLATILE
FUELS THAT CAN CAUSE A FIRE OR
EXPLOSION.
- NEVER store kerosene in the living space.
Kerosene should be stored in a well ventilated area
outside the living area.
- NEVER store kerosene in direct sunlight or near a
source of heat.
- NEVER use kerosene that has been stored from
one season to the next. Kerosene deteriorates
over time. OLD KEROSENE WILL NOT BURN
PROPERLY IN THIS HEATER.
127(.HURVHQHVKRXOGRQO\EHVWRUHGLQDEOXH
FRQWDLQHUWKDWLVFOHDUO\PDUNHG³.HURVHQH´
1HYHUVWRUHNHURVHQHLQDUHGFRQWDLQHU5HGLV
DVVRFLDWHGZLWKJDVROLQH
9HQWLODWLRQ
5LVNRILQGRRUDLUSROOXWLRQDQG&DUERQ
0RQR[LGH3RLVRQLQJ8VHKHDWHURQO\LQZHOO
YHQWLODWHGDUHDV
5HIHUWR6DIHW\,QIRUPDWLRQRQSDJHVIRU
LQIRUPDWLRQDERXW&DUERQ0RQR[LGH3RLVRQLQJ
-
$/:$<6 provide a fresh air opening in the heated
space of at least three square feet (2,800 sq. cm)
for each 100,00 Btu / Hr. of heater output. Provide
a larger opening if more heaters are being used.
As an example, a 125T-KFA will require:
- A two car garage door open 6 inches or
- A single car garage open 9 inches, or
- Two (2) 32” windows open 15”
0LQLPXP9HQWLODWLRQ2SHQLQJ1HHGHG
45-KFA
70T-KFA
125T-KFA
175T-KFA
215T-KFA
1.4 ft.²
2.1 ft.²
3.8 ft.²
5.3 ft.²
6.5 ft.²
1250 cm²
1950 cm²
3480 cm²
3760 cm²
5990 cm²
(OHFWULFDO2XWOHW
- Never plug an appliance with more than a 5 amp
rating into this outlet (See Figure 8).
- Always keep outlet covered when not in use.
1(9(5),//7+()8(/7$1.
,1'2256$/:$<6),//
7+(7$1.287'2256%(685(7+$7
7+(+($7(5,621/(9(/*5281':+(1
)8(/,1*$1'1(9(529(5),//7+(7$1.
CAUTION
1(9(55()8(/7+,6+($7(5
:+,/(,7,6+2725
23(5$7,1*),5(25(;3/26,21&28/'
5(68/7
DANGER
&$5%210212;,'(32,621,1*
0$($'72'($7+
DANGER
Figure 8
Electrical Outlet
Storage Drawer
(125T / 175T / 215T-KFA Only)
7
'212786(*$62/,1(25
&5$1.&$6('5$,1,1*6
WARNING