Burner and nozzle specifications – Cannon 50cm Free Standing Gas Cooker C50GLW User Manual
Page 9
9
Burner and Nozzle Specifications
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
Thermal
Power
kW
(p.c.s.*)
Thermal
Power
kW
(p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Thermal
Power
kW
(p.c.s.*)
Nozzle
1/100
Flow*
l/h
(mm)
Nominal
Reduced
(mm)
(mm)
***
**
Reduced
(mm)
Fast
(Large)(R)
100
94
2,60
0,70
41
80
189
186
0,70
118
248
Semi Fast
(Medium)(S)
75
69
1,90
0,40
30
70
138
136
0,40
104
181
Auxiliary
(Small)(A)
51
46
1,00
0,40
30
52
73
71
0,40
76
95
Oven
-
2,60
0,60
36
71
189
186
0,60
115
248
Grill
-
2,50
1,30
63
80
182
179
1,30
122
238
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
3
S
S
R
A
C50GLB
C50GLK
C50GLW
C50GLS
C50GLX
C50LCIK
C50LCIW
C50GCIK
C50GCIW
This manual is related to the following products: