Arctic compact 12-20 ul – Cecilware 12-20 UL User Manual
Page 4
4
ARCTIC COMPACT 12-20 UL
6 Gravity faucet: extract the piston and then remove the
dispensing handle (see figure 3).
figure 3
7 Slide drip tray out and empty it.
5. 3. 2 CLEANING
1 Prepare at least two gallons of a mild cleaning solution of
warm (45-60 °C 120-140 °F) potable water and dishwashing
detergent. Do not use abrasive detergent.
Important: if present, follow label directions, as too strong a
solution can cause parts damage, while too mild a solution will
not provide adequate cleaning.
2 Using a brush, suitable for the purpose, thoroughly clean all
disassembled parts in the cleaning solution.
3 Do not immerse the lighted top covers in liquid. Wash them
apart with the cleaning solution. Carefully clean their undersi-
des.
4 In the same manner clean the evaporator cylinder(s) using
a soft bristle brush.
5 Rinse all cleaned parts with cool clean water.
5. 3. 3 SANITIZING
Sanitizing should be performed immediately prior to
starting the machine. Do not allow the unit to sit for
extended periods of time after sanitization.
1 Wash hands with a suitable antibacterial soap.
2 Prepare at least two gallons of a warm (45-60 °C 120-
140 °F) sanitizing solution (100 PPM available chlorine concen-
tration or 1 spoon of sodium hypoclorite diluted with two litres of
water) according to your local Health Codes and manufactu-
rer’s specifications.
3 Place the parts in the sanitizing solution for five minutes.
4 Do not immerse the lighted top covers in liquid. Carefully
wash their undersides with the sanitizing solution.
5 Place the sanitized parts on a clean dry surface to air dry.
6 Wipe clean all exterior surfaces of the unit. Do not use abra-
sive cleaner.
5. 3. 4 ASSEMBLY
1 Slide the drip tray into place.
2 Pinch tube faucet: push the dispensing handle (1) and
insert the pinch tube into its vertical seat in the bowl bottom(2).
Lightly pull the pinch tube end downwards til itl is well arranged
(3) (see figure 4).
figure 4
3 Gravity faucet: install the faucet handle and the piston with
its gasket (see figure 5).
figure 5
4 Fit the bowl gasket to the evaporator. Note: the largest brim
of the gasket must face against the drip plate (see figure 6).
figure 6
IMPORTANT
Do not attempt to wash any machine components in a
dishwasher.
ATTENTION
Before any disassembly and/or cleaning procedure make
sure that the dispenser is disconnected from its power
source.
IMPORTANT
In order to prevent any damages to the dispenser use
only a detergent suitable with plastic parts.
ATTENTION
When cleaning the machine, do not allow excessive
amounts of water around the electrically operated com-
ponents of the unit. Electrical shock or damage to the
machine may result.