Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

20003457

Clearance Requirements

Minimum Clearances to Combustible Materials

Measure side clearances as shown in Figures 3, 4 and
5 from the outer edge of the cast iron stove top.
Measure rear clearances from the outermost surface of
the steel rear skirt.

The PDV20 and SDVR heaters are approved for
installation into an alcove constructed of combustible
materials to the dimensions and clearances shown on
the next page.

The same clearances apply in a standard parallel
installation.

Minimum Clearances

C

L

18³⁄₄

"

(476mm)

2

¹⁄₂

"

(64mm)

6"

(150mm)

6"

(150mm)

Parallel Installation

C

L

18

³⁄₄

"

(476mm)

2

¹⁄₂

"

(63mm)

6

"

6

"

PDV20

SDVR

ST128c

ST128a

Fig. 3 Parallel installation minimum clearances and flue centerline.

2" (50mm)

2"

(50mm)

7

¹⁄₂

"

(190mm)

Max. Vent

Length

20" (508mm)

Corner Installation

PDV20

Max. Vent

Length

20" (508mm)

7

¹⁄₂

"

(190mm)

2" (50mm)

2"

(50mm)

SDVR

ST129a

Fig. 4 Corner installation minimum clearances.

WARNING:

• Always maintain required

clearances (air spaces) to nearby combustibles
to prevent fire hazard. Do not fill air spaces with
insulation. All venting components must
maintain a 1" (25mm) clearance to combustible
materials. Maintain a 6” (150mm) clearance
when using single wall pipe. Maintain a 2”
(51mm) clearance when venting straight off the
rear.

• The gas appliance and vent system must be

vented directly to the outside of the building
and never be attached to a chimney serving a
separate solid fuel or gas-burning appliance.

• Refer to the manufacturer's instructions

included with the venting system for complete
installation procedures.