cord contains at least the minimum wire size required.
(See Figure C.)
5.
If you are using one extension cord for more than one tool, add the nameplate
amperes
and use the sum to determine the required minimum cord size.
(See Figure C.)
6.
If you are using an extension cord outdoors, make sure it is marked with the suffix “W-
A” (“W” in Canada) to indicate it is acceptable for outdoor use.
7.
Make sure your extension cord is properly wired and in good electrical condition. Always
replace a damaged extension cord or have it repaired by a qualified electrician before
using it.
8.
Protect your extension cords from sharp objects, excessive heat, and damp or wet
areas.
RECOMMENDED MINIMUM WIRE GAUGE FOR ExTENSION CORDS*
NAMEPLATE
AMPERES
(At Full Load)
ExTENSION CORD LENGTH
25 Feet
50 Feet
75 Feet
100 Feet
150 Feet
0 - 2.0
18
18
18
18
16
2.1 - 3.4
18
18
18
16
14
3.5 - 5.0
18
18
16
14
12
5.1 - 7.0
18
16
14
12
12
7.1 - 12.0
18
14
12
10
-
12.1 - 16.0
14
12
10
-
-
16.1 - 20.0
12
10
-
-
-
FIGURE C
* Based on limiting the line voltage drop to five
volts at 150% of the rated amperes.
SYMBOLOGY