Venting installation examples – Cumberland Stove Works OMMF3500 User Manual
Page 17
INSTALLATION AND OPERATION MANUAL
MF3500G, MF3500S, MF3500B Models
Page 5
800-345-6007
CumberlandStoveWorks.com
VENT TERMINATION CLEARANCES
CLEARANCE
4 feet
Clearance below or beside any door or window
that opens.
1 foot
Clearance above any door or window that
opens.
3 feet
Clearance from any adjacent building.
7 feet
Clearance from any grade when adjacent to
public walkways.
2 feet
Clearance above any grass, plants, or other
combustible materials.
3 feet
Clearance from any forced air intake of any
appliance.
2 feet
Clearance below eaves or overhang.
1 foot
Clearance horizontally from combustible
wall.
3 feet
Clearance above the roof.
2 feet
Clearance above the highest point on the roof
within 10 feet.
VENTING INSTALLATION EXAMPLES
STRAIGHT INSTALLATION
Inside Vertical Rise, Horizontal Termination
FLOOR PROTECTION
STRAIGHT INSTALLATION
Outside Vertical Rise, Through Wall Installation
FLOOR PROTECTION