Troubleshooting, Odgsr series outdoor gas fireplace – Vermont Casting ODGSR36A EN User Manual

Page 13

background image

13

ODGSR Series Outdoor Gas Fireplace

20007114

Troubleshooting

FP396

Gas Supply On

Supply Line Hooked up

Shutoff Valve Open

NO

NO

NO

NO

Lockout has engaged. Wait 60

seconds and try again.

Piezo not tight enough for good

ground.

For spark at electrode while

depressing Piezo (Red Button)

1/8" gap to pilot hood needed.

All wiring connections

Replace Piezo Ignitor

Thermodisk

For Air in the lines

Thermopile needs a minimum

325mV. Adjust pilot flame height.

All wiring connections

Replace Thermopile

Thermocouple needs a minimum

of 14mV.

Defective valve. Turn to pilot,

meter should read greater than

100mV.

Thermodisk

Pilot Lights with

Piezo Ignitor

YES

YES

YES

YES

Pilot Stays Lit

Pilot Lights Main

Burner

System OK

START

CHECK

Wall switch is not turned on.

Watch for grounded wires!

Thermopile needs a minimum

325mV

Plugged burner orifice

Doors not fully open (Fig. 10)

FP396

NVC-standing pilot troubleshooting

5/6/98

Nova SIT 820 Standing Pilot