Troubleshooting
FP396
Gas Supply On
Supply Line Hooked up
Shutoff Valve Open
NO
NO
NO
NO
Lockout has engaged. Wait 60
seconds and try again.
Piezo not tight enough for good
ground.
For spark at electrode while
depressing Piezo (Red Button)
1/8" gap to pilot hood needed.
All wiring connections
Replace Piezo Ignitor
Thermodisk
For Air in the lines
Thermopile needs a minimum
325mV. Adjust pilot flame height.
All wiring connections
Replace Thermopile
Thermocouple needs a minimum
of 14mV.
Defective valve. Turn to pilot,
meter should read greater than
100mV.
Thermodisk
Pilot Lights with
Piezo Ignitor
YES
YES
YES
YES
Pilot Stays Lit
Pilot Lights Main
Burner
System OK
START
CHECK
Wall switch is not turned on.
Watch for grounded wires!
Thermopile needs a minimum
325mV
Plugged burner orifice
Doors not fully open (Fig. 10)
FP396
NVC-standing pilot troubleshooting
5/6/98
Nova SIT 820 Standing Pilot