beautypg.com

Introduction – cont’d, Operation, Room heater specifications – Louisville Tin and Stove VFT202 User Manual

Page 3: Safety instructions, Page 3, As applicable

background image

INTRODUCTION – CONT’D.

For your protection this heater is equipped with an Oxygen Depletion Sensor (ODS) pilot system. Never operate heater if
ODS has been damaged or tampered with as this could expose you to Carbon Monoxide (a colorless, odorless gas) that
could result in injury or death. Early signs of Carbon Monoxide poisoning resemble influenza, with headaches, dizziness,
or nausea. If you develop these symptoms GET FRESH AIR AT ONCE. Turn off heater and call a qualified serviceman to
check heater. Some people are more affected by Carbon Monoxide than others: Including pregnant women, persons with
a heart or lung disease, anemia, those under the influence of alcohol, and those at high altitudes.

OPERATION

Infrared heaters “heat like the sun” with almost instantaneous, safe, clean burning “waves” of infrared heat. Like the sun,
they must “see” the object to be heated. Make sure they are installed away from furniture or any other object which
might block the infrared “waves”. The Cozy thermostatically controlled units offer the additional benefit of automatically
cycling the heating to maintain just the right room temperature. Ventfree gas room heaters are designed strictly for
“supplemental” room heat use and should never be installed as “sole source heating”.

ROOM HEATER SPECIFICATIONS

Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model
Number is correct and that the room heater is equipped for the type gas you intend to use.

SAFETY INSTRUCTIONS

1)

Keep burner and control compartment clean.

2)

Due to high temperatures, the heater should be located out of traffic and away from furniture and draperies.

3)

Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns
or clothing ignition.

4)

Young children should be carefully supervised then they are in the same room with this heater.

5)

Do not place clothing or other flammable material on or near the heater.

6)

Any safety screen or guard removed for servicing must be replaced prior to operating the heater.

Page 3

MODEL NUMBER

MANUAL MODELS

THERMOSTAT MODELS

NATURAL GAS

VFM63

VFM103

VFM203

VFM303

VFT101

VFT201

VFT301

PROPANE GAS

VFM64

VFM104

VFM204

VFM304

VFT102

VFT202

VFT302

TYPE CONTROL

MAN.

MAN.

MAN.

MAN.

T-STAT

T-STAT

T-STAT

BULB

BULB

BULB

HEIGHT

22-1/2”

22-1/2”

22-1/2”

22-1/2”

22-1/2”

22-1/2”

22-1/2”

WIDTH

11-1/2”

14-9/16”

20-11/16”

26-13/16”

14-9/16”

20-11/16”

26-13/16”

DEPTH

7 ”

7 ”

7 ”

7 ”

7 ”

7 ”

7 ”

INPUT (BTU/HR.)

5,500

10,000

LO / 10,000

LO / 10,000

10,000

20,000

30,000

HI / 20,000

MED./20,000

HI / 30,000

Gas Supply Line Size

½”

½”

½”

½”

½”

½”

½”

Optional CVF Blower

NO

NO

YES

YES

NO

YES

YES

Optional Floor Stand

NO

YES

YES

YES

YES

YES

YES

Bathroom Installation

YES

NO

NO

NO

NO

NO

NO

Bedroom Installation

YES

YES

NO

NO

YES

NO

NO

Piezo Ignitor

YES

YES

YES

YES

YES

YES

YES

Shipping Weight

16 LB.

22 LB.

30 LB.

35 LB.

22 LB.

30 LB.

35 LB.

As applicable:

1. An unvented room hetaer having an input rating of more than 10,000 Btu per hour shall not be installed in a bedroom
or bathroom; or
2. An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom.

This manual is related to the following products: