APPENDIX B
CLEARANCE TO COMBUSTIBLES
The following clearances meet the minimum requirements for a safe installation
Sidewall:
18 inches measured from the outer door edge hinge
Ceiling:
7 feet from the base of the fireplace
Fireplace Enclosure:
Bottom:
0
Side:
1 inch
Back:
½ inch
Top:
2 ½ inches. Header may rest on top of top spacer.
NOTE:
Combustible material cannot be used in the space directly above the fireplace.
Mantel:
Ducts closed with top grill open
71 inches
Mantel:
With 31/2 inches brick on front
59 inches
Mantel:
Ducts open & top grill open
55 inches
Mantel:
Ducts open & top grill closed
45 inches
Hearth:
Fireplace Width (42 + 8 + 8)
58 inches
Hearth:
Depth from front of fireplace
24 inches
NOTE: Mantel measurements are from the bottom of the Inglenook Fireplace unit.