Address Description:

Multiple Chief devices can be used on the same network by setting each device to a different address.

Note: All units ship with a default address of 0

Address Table:

Addresses are set using dipswitches located next to power inlet on mount.

(See figure 31)

Status Table:

Status is a 4 character hex representation of a 16 bit value

Example:

Fully retracted, parameter changes disabled, no errors, not moving, in home position.

0, 0, 0, 0, 0, 0, 1, 0, 0, 0, 0, 0, 0, 0, 0, 1

Value returned as status: 0201 (hex)

Errors:

If no response message is received, the device does not exist on the network, or there was an error during message transmission

See Error Message Table

Error Message Table:

Switch # 6

Switch # 7

Switch # 8

Address

OFF

OFF

OFF

00

ON

OFF

OFF

01

OFF

ON

OFF

02

ON

ON

OFF

03

OFF

OFF

ON

04

ON

OFF

ON

05

OFF

ON

ON

06

ON

ON

ON

07

Bit

1

0

Description

0

TRUE

FALSE

In Home Position?

1

TRUE

FALSE

Move in Progress?

2

TRUE

FALSE

Network Operation in Progress?

3

TRUE

FALSE

Parameter Changes Enabled?

4

TRUE

FALSE

Network Command Error?

5

-

-

Not Used - Permanently @ 0

6

-

-

Not Used - Permanently @ 0

7

-

-

Not Used - Permanently @ 0

8

TRUE

FALSE

At Extend Limit

9

TRUE

FALSE

At Retract Limit

10

-

-

Not Used - Permanently @ 0

11

-

-

Not Used - Permanently @ 0

12

-

-

Not Used - Permanently @ 0

13

-

-

Not Used - Permanently @ 0

14

-

-

Not Used - Permanently @ 0

15

-

-

Not Used - Permanently @ 0

0x01

Command Not Supported

Returned when a device does not support the command sent

0x02 Index

Error

Returned when the index value sent is out or range for the device

0x03

Value Error

Returned when the data value sent is out of range for the device

0x04 Message Length Error

Returned when the length of the command message is incorrect for the command code

0x05 Write Protect Error

Returned when parameter changes are attempted without first enabling parameter changes