Battery pack replacement and storage, Battery pack replacement procedure, Storage – CyberPower Systems 3000 VA User Manual

Page 2: Technical specifications, Definitions for illuminated led indicators

background image

loads uninterrupted.

Ethernet(RJ-45) Network Protection Ports

These ports are the protection for your computer network cable.

Serial Port to PC

Professional Rack Mount Series UPS provides two
serial ports to allow connection and communication
between the UPS and two computers.
The two serial ports allow connection and

mary computer (with PowerPanel

®

Business Edition installed) is the computer that you will

:

art to

2.

llowing the

BATTERY PACK REPLACEMENT AND STORAGE

AUTION!

communication from the DB-9 serial or USB port
on the computer to the UPS unit. These interfaces
are also compatible with the UPS service provided
by Windows 98, Windows ME, Windows 2000,
Windows NT, Windows XP, Windows Server
2003.

The Pri
use to control the UPS and make any change to the operation of the UPS. The Secondary
computer (with PowerPanel

®

installed) is unable to exhibit any control over the UPS.

When power failure occurs, one of the following shutdown sequences will be executed

1. If the Primary and Secondary serial ports are both in use: the Primary computer will st

count down (user controlled delay) for shutdown (User Control delay can be set in the
PowerPanel

®

Business Edition software. Recommended time is 5 minutes). Once the Primary

computer is shutdown, the UPS will signal the Secondary computer and initiate the Secondary
to shutdown. The UPS default shutdown time is 2 minutes. Therefore, it is recommended that
Secondary computer is set to shutdown within 1 minute in PowerPanel

®

Software.

If only the Secondary serial port is in use: the Secondary computer will shutdown fo

user settings in PowerPanel

®

Software. However, the Secondary computer will not able to

signal the UPS to shut down. Therefore, the UPS will only power off when it is in low battery.

C

Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery

pack. Do not open the battery pack and service the batteries inside. If you have questions, contact
your dealer or call the number in this manual
for information on battery replacement.
CAUTION! Use only CyberPower Battery Pack for replacement. See your dealer for this model.
CAUTION! The battery may present the risk of electrical shock. Do not dispose of batteries in a
fire
, as it may explode. Follow all local ordinances regarding proper disposal of batteries.
CAUTION! Do not open or mutilate the batteries. Release electrolyte is harmful to the skin and eyes

ATTERY PACK REPLACEMENT PROCEDURE

and may be toxic.

B

er source.

UPS.

. Turn off and unplug all connected equipments.

1
2. Turn the UPS off and unplug it from the AC pow
3. Unplug the black and red wire of the Battery Pack from the
4. Follow the Hard Installation Guide to connect a new Battery Pack to the UPS.

.

STORAGE

r UPS and disconnect its power cord from the wall outlet. Disconnect all cables

TROUBLE SHOOTING

irst turn off you

F
connected to the UPS to avoid battery drain. To store your UPS for an extended period, cover it and
store with the battery fully charged. Recharge the battery every three months to insure battery life. If
the battery remains uncharged for an extended period of time, it may suffer permanent loss of
capacity.

Problem

Possible Cause

Solution

Batter

ed.

Recharge the batte

the UPS plugged

ies are not fully charg

ry by leaving

in.

The

ot

Battery is slightly worn out.

UPS does n

perform expected
runtime.

Contact CyberPower Systems at
[email protected]

The on/off switch is designed to

nds and then turn

prevent damage by rapidly
turning it off and on.

Turn the UPS off. Wait 10 seco
the UPS on.

The unit is not connected to an

e connected to a 220-240V

AC outlet.

The unit must b
50/60Hz outlet.

The battery is worn out.

r Systems at

Contact CyberPowe
[email protected]

The UPS will not

Mechanical problem.

t

turn on.

Contact CyberPower Systems a
[email protected]

Circuit breaker is tripped due to

ne piece of

overload.

Turn the UPS off and unplug at least o
equipment. Wait 10 seconds, reset the circuit
breaker and then turn the UPS on.

Batteries are discharged

t 4 hours.

Allow the unit to recharge for at leas

Outlets do not

o

y a

provide power t
equipment

Unit has been damaged b
surge or spike.

Contact CyberPower Systems at
[email protected]

The serial/USB cable is not

the UPS unit and

connected.

Connect the serial/USB cable to
an open serial port on the back of the computer.
You must use the cable that came with the unit.

The serial/USB cable is

ort.

connected to the wrong p

Try another serial/USB port of your computer.

The unit is not providing battery
power.

Shut down your computer and turn the UPS off.
Wait 10 seconds and turn the UPS back on. This
should reset the unit.

PowerPanel

®

n or

al cable is not the cable

e included with the unit for

Business Editio
PowerPanel

®

is

inactive (all icons
are gray).

The seri
that was provided with the unit.

You must use the cabl
the software.

Block Diagram


TECHNICAL SPECIFICATIONS

Model

PR3000E

IN

OUT

OUT

Capacity (VA)

3000VA

Capacity (Watts)

2200W

Input

Voltage Range

220-240Vac

Frequency Range

50/60 Hz

Output

On Battery Output Voltage

Pure Sine Wave at 230Vac +/- 7%

On Battery Output Frequency

50/60 Hz

Transfer Time (Typical)

4ms

Overload Protection

On Utility: Circuit Breaker, On

ry: Internal Current Limiting

Batte

Surge Protection and Filtering

Lightning / Surge Protection

Yes

Network Protection

RJ45(On

ne Out)

e In/O

Physical

Total # of UPS Receptacles

5 ( 3 IEC+ 2 Schuko)

Maximum Dimensions

2U Rack * 2

Weight (Kg)

55.5

Battery

Sealed Maintenance Free Lead

12V/7AHx8

Acid Battery

Typical Recharge Time

8 Hours

Warning Diagnostics

Indicators

Power On, Using Battery, AVR, Load Level, Battery Level

Audible Alarms

On Battery, Low Battery, Overload

Environmental

Operating Temperature

+ 32°F to 95°F (0°C to 35°C)

Operating Relative Humidity

0 to 95% NON-CONDENSING

Communication

PowerPanel

®

Business Edition

Windows 98/ME/NT/2000/XP/Server 2003

Software

Management

Self-Test Manual

Self-Test

Auto-Charger Yes

Auto-Restart Yes

USB Yes

SNMP / HTTP Network

Optional

DEFINITIONS FOR ILLUMINATED LED INDICATORS

Power

On

AVR

Using

Circuit

Battery

Breaker

Alarm

Condition

On Off Off Set Off

Normal

On Slow

flash

Off

Set

Off

AVR- Max. boost 13% o

oltage for output

f input v

regulation while input voltage is from 8% to 15%
under nominal.

On Rapid

flash

Off

Set

Off

AVR- Max. boost 26% of input voltage for output
regulation while input voltage is from 15% to 26%
under nominal.

ON On Off Set Off

AVR- Max. buck 11% of input voltage for output

ver

regulation while input voltage is from 8% to 26% o
nominal.

Off Off On Set

Two

Beeps

ilure- The UPS is providing battery power to

Utility Fa
the Battery-Power Supplied outlets.

Off Off On Set

Rapid

attery power.

Beeps

Utility Failure- The UPS is providing b
Rapid beeps indicate the battery will run out of charge
within a few minutes.

On/Off

On/ Off

On/Off

Set Long

Beep

Overload- Turn the UPS off and unplug at least one

/Flash

piece of equipment from the UPS. Wait 5 seconds,
reset the circuit breaker and restart the UPS.

Off Off On Up

Long

Beep

Overload- Turn the UPS off and unplug at least one
piece of equipment from the UPS. Wait 5 seconds,
reset the circuit breaker and restart the UPS.

Off Off Off Set Off

Surge Protection Malfunction- Power surge has
damaged the unit. Please contact CyberPower
Systems.

or more information, visit

eu.cyberpowersystems.com

F

or contact

yberPower Systems, B.V. (Netherlands)

Netherlands

[email protected]

C

Flight Forum 3545, 5657DW Eindhoven, The

Tel: + 31 73 649 1209, Fax : +31 (0)40 2340314 E-MAIL:

sa

yberPower Systems, Inc. (USA)

akopee, MN 55379, U.S.A.

rpowersystems.com

C

4241 12th Avenue East Suite 400 Sh

sales@cybe

Tel: +1 952 4039500, Fax: +1 952 4030009, E-MAIL:

ntire contents copyright ©2004 CyberPower Systems, B.V., All rights reserved. Reproduction in

yberPower warrants to you, the original purchaser, that CyberPower UPS will be free from defects

.

E

Input

AVR Switch

Battery

Charger

Transformer

Output

Battery

Inverter

(DC/AC)

®

®

and PowerPanel

whole or in part without permission is prohibited. PowerPanel

Plus are

trademarks of CyberPower Systems, (USA) Inc.

C

in design, assembly, materials and workmanship for two years ( battery is only one year) from the

date of original purchase. Any warranty services, please contact your local dealers or distributors