Operation, Stardance natural vent gas heater – Vermont Casting SNV30 User Manual
Page 13

13
Stardance Natural Vent Gas Heater
20007067
Operation
Your First Fire
Read these instructions carefully and familiarize
yourself with the burner controls shown in Figure 25.
Locate the pilot assembly, Figure 22. Follow the lighting
instructions on Page 14 exactly.
During the first fire, it is not unusual to smell some
odor associated with new logs, paint and metal being
heated. Odors should dissipate within an hour or so,
however, you can open a window to provide fresh air to
alleviate the condition.
Pilot and Burner Inspection
Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in Figure
24. If flame patterns are incorrect, turn the heater off.
Contact your dealer or a qualified gas technician for as-
sistance. Do not operate the heater until the pilot flame
is correct.
Follow regular maintenance procedures as described
on Page 19.
ST477
Stardance
pilot location
10/4/00
Fig. 22 Pilot Assembly location.
ST476
Pilot As-
sembly
Flame & Temperature Adjustment
For stoves equipped with HI/LO valves, flame adjust-
ment is accomplished by rotating the HI/LO adjustment
knob located near the center of the gas control valve.
(Fig. 23)
Flame Characteristics
It is important to periodically perform a visual check
of the pilot and the burner flames. Compare them to
Figure 24. If any of the flames appear abnormal, call a
service person.
��
��
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
HV102
Honeywell hi/lo knob
4/5/99 djt
Fig. 23 Flame adjustment knob for Honeywell valve.
CO105c
Pilot flame
4/10/00 djt
LG143
Fig. 24 Correct pilot and burner flame pattern.
LG142
Stardance
Install logs 2
12/11/00 djt
Red Glow
CO105c
�������
�
��������������
������������
������������������
�������������
��������������������
���������������
The Stardance is operated with the front plate in place
with the doors open or closed. To open the front doors,
pull forward to separate the magnetic catch.
CAUTION: DO NOT TOUCH DOORS WHEN
HOT!