Water filtration system performance data sheet, Brand: metro model: chp-04al, General operating information – Coway CHP-04AL User Manual

Page 34

background image

33

Water Filtration System Performance data Sheet

brand: metro

model: CHP-04Al

This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53, and 58 for

the reduction of the substances listed below. The concentration of the indicated substances in water entering the

system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as

specified in NSF/ANSI 42, 53, and 58

Substance

Max. Allowable

Concentration

(mg/L)

Average

Influent

(mg/L)

Average

Effluent

(mg/L)

Minimum

Percent

Reduction (%)

Average

Percent

Reduction (%)

Arsenic (Pentavalant)

0.010

0.05

0.006

79.1

87.7

Barium

2.0

10

1.4

83.5

86.6

Radium 226/228

5pCi/L

25pCi/L

5pCi/L

N/A

N/A

Cadmium

0.005

0.031

0.002

89.0

92.7

Chromium (Hexavalent)

0.1

0.358

0.023

93.8

95.1

Chromium (Trivalent)

0.1

0.367

0.028

93.8

95.7

Lead

0.010

0.153

0.005

93.6

95.1

Nitrate/Nitrite

10

29.6

4.8

78.5

83.7

Selenium

0.05

0.117

0.003

96.0

97.8

TDS

<187.5

741.5

55.1

90.0

92.6

Aesthetic Chlorine

INNOSENSE

≥ 50%

2.07

0.56

54.53

72.8

FINE POST CARBON

≥ 50%

1.96

0.53

55.0

72.8

VOC*

INNOSENSE

≥ 95% reduction

0.327

0.0052

96.20

98.4

FINE POST CARBON

≥ 95% reduction

0.317

0.005

96.2

98.5

While testing was performed under laboratory conditions, actual performance may vary.

General Operating information:

Rated Capacity

INNOSENSE FILTER

359 gallons (for VOC)

7,523 gallons (for Aesthetic Chlorine)

FINE POST-CARBON

402 gallons (for VOC)

1,453 gallons (for Aesthetic Chlorine)

Min-Max operating pressure:

20 ~ 120 psi (14 ~ 8.4 kgf/cm

2

)

Min-Max feed water temperature:

41 ~ 95 ºF (5 ~ 35 ºC)

Rated Service Flow

0.07 GPM (for VOC)

0.5 GPM (for Aesthetic Chlorine)

Daily Water Production Rate

53.3 GPD

Product Efficiency Rating

31.0 %

Electrical Requirements:

120 Vac / 60Hz

• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection

before or after the system.

• Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user

responsibility, and parts and service availability.

• The influent water to the system shall include the following characteristics:

o No organic solvents

o Chlorine: < 2 ppm

o pH: 7 - 8

o Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)

o Iron: < 2 ppm

o Turbidity: < 1 NTU

o Hardness: < 1000 mg/L