beautypg.com

30 table 3 – Centurion CP72SR5 User Manual

Page 32

background image

30

TABLE 3

PEDESTRIAN AUTOCLOSE

NORMAL AUTOCLOSE

AUTOCLOSE OVERRIDE

PREFLASH TIME

COURTESY LIGHT

COLLISION COUNTER

11

1 SEC

1 SEC

1 SEC

1 SEC

10 SEC

1 COUNT

3

6

12

5

8

MAIN

MENU

No of times

L1 flashes

Each flash

of STATUS

represents

UNIT OF

MEASURE

CRAWL DISTANCE (D3/D5)

350 MM

13

COAST MODE (A5)

10 MM

13

15 SEC

5 SEC

5 SEC

4 COUNTS

5 SEC

3 SEC

12x10 SEC

FACTORY

DEFAULTS

1x350mm

30mm

TURBO MODE: TO SPEED UP THE COUNTING WHILE SELECTING MAIN
MENU ITEMS TEMPORARILY CONNECT “PED” TERMINAL TO “COM”

DISTANCE BETWEEN

MARKER AND PINION

750mm

STATUS FLASH

COUNT

CRAWL

DISTANCE

700mm

2

1100mm

1050mm

3

500mm

1

350mm

DEFAULT

† THE CRAWL DISTANCE IS A LENGTH OF TRAVEL WHICH ALLOWS
THE GATE TO SLOW DOWN BEFORE REACHING THE END STOP. FOR
HEAVIER GATES WITH LESS FRICTION, THE CRAWL DISTANCE MAY
HAVE TO BE INCREASED. WHEN INCREASING THE CRAWL
DISTANCE, THE POSITION OF THE ORIGIN MARKER (ITEM 66 PAGE
15) MUST BE MOVED.