MS850 Owner’s Manual - Page 13
You can use this chart to quickly identify and interpret your system’s chirp indications and LED
flashes.
Reference Chart
1 chirp
arming
normal arming
1 + 4 chirps
arming
door, hood, or trunk is open
Output
When
Status
2 quick chirps
arming
Valet Mode is on
LED double flashes
Valet Mode
Starter Defeat Activated
2 chirps
disarming
normal disarming
1 long
disarming
Tamper Alert - system was triggered
no chirps
after Tamper Alert
ignition
1 chirp
after Tamper Alert
door
2 chirps
after Tamper Alert
shock sensor
3 chirps
after Tamper Alert
hood or trunk
no LED flashes
after Tamper Alert
ignition
1 LED flash
after Tamper Alert
door
2 LED flashes
after Tamper Alert
shock sensor
3 LED flashes
after Tamper Alert
hood or trunk
1 chirp
while Armed
Warn Away
4 chirps
with ignition key on
Sensor Test mode on
1 chirp
in Sensor Test mode
impact detected
Double chirps
1 minute after disarming
Automatic Rearming
(for 10 seconds)
LED flashing quickly
ignition key off
Passive Arming sequence started
Two chirps
ignition key off
Full Time System Diagnostics
1 LED flash
after Full Time Sys. Diag.
door
2 LED flashes
after Full Time Sys. Diag.
shock sensor
3 LED flashes
after Full Time Sys. Diag.
hood or trunk
Double chirps
while Armed
System Triggered
(Passive Arming Entry Delay Warning)