Installation instructions – Cannon Windsor Mk2 10297G Mk2 User Manual
Page 27

TECHNICAL DATA
DIMENSIONS
Height
900 - 915mm
Width
600mm
Depth
595mm (excluding door handles)
GENERAL
Gas connection
Rp
1
/
2
(
1
/
2
” BSP female)
Gas Supply
Natural gas models – G20 at 20 mbar
Pressure test point
Grill injector
Gas rate adjustment
None
Aeration adjustment
None
Electrical connection
Flexible cord fitted with a 3 pin 13 amp plug
230/240V a.c. 50Hz. 3A fuse.
27
INSTALLATION INSTRUCTIONS
HEAT
INPUT
NATURAL GAS
MODELS
BURNER
INJECTOR
3.8 kW
GRILL
150
2.7 kW
OVEN
120
3.0 kW
HOTPLATE
Front left and rear right
134
1.8 kW
HOTPLATE
Front right and rear left
109