TECHNICAL DATA

DIMENSIONS
Height

900 - 915mm

Width

600mm

Depth

595mm (excluding door handles)

GENERAL
Gas connection

Rp

1

/

2

(

1

/

2

” BSP female)

Gas Supply

Natural gas models – G20 at 20 mbar

Pressure test point

Grill injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

Flexible cord fitted with a 3 pin 13 amp plug
230/240V a.c. 50Hz. 3A fuse.

27

INSTALLATION INSTRUCTIONS

HEAT

INPUT

NATURAL GAS

MODELS

BURNER

INJECTOR

3.8 kW

GRILL

150

2.7 kW

OVEN

120

3.0 kW

HOTPLATE
Front left and rear right

134

1.8 kW

HOTPLATE
Front right and rear left

109