Cabletron Systems 9E531-24 User Manual
Page 23
2-3
Installing the SmartSwitch 9000 Module
An eight-position DIP switch is located on the module card as shown in
Figure 2-1. The function of the switches are listed in Table 2-1.
See the Cautions at the end of this table.
Table 2-1. Function of DIP Switch
Switch
Function
Description
8
Clear
Password
1
When toggled, this switch clears user-entered
passwords stored in NVRAM, and restores the
default passwords. Once reset you can use the
defaults or enter new passwords.
7
Clear
NVRAM
2
The module uses NVRAM to store user-
entered parameters such as IP addresses,
device name, etc. To reset these parameters to
the factory defaults, toggle this switch. Once
reset, you can use the defaults or enter new
parameters, which are stored in NVRAM
when the module is powered down, and
remain there until the switch is toggled again.
6
Force BootP
Download
Toggling this switch after pulling the board
out of the SmartSwitch 9000, clears download
information from NVRAM and forces image
files to be downloaded from the station
connected to the EPIM on the Environmental
Module configured to act as that modules’
B
oot
P server. (See section titled Using DIP
5
Reserved
For Factory Use Only
4
Reserved
For Factory Use Only
3
Reserved
For Factory Use Only
2
Reserved
For Factory Use Only
1
Reserved
For Factory Use Only
1. Caution: Do not toggle Switch 8 unless you intend to reset the user-
configured passwords to their factory default settings.
2. Caution: Do not toggle Switch 7 unless you intend to reset the user
parameters to the factory default settings.
!