3
Table 1.1: Summary of PPs Flex Venting Options
VENT OPTION #
9
10
CLASSIFICATION USED IN THIS MANUAL
PPs FLEX
(MASONRY)
PPs FLEX
(MASONRY)
ILLUSTRATED IN FIGURE
1.0
1.0
VENT PIPE PENETRATION THROUGH STRUCTURE
CHIMNEY CAP
CHIMNEY CAP
AIR INTAKE PENETRATION THROUGH STRUCTURE
CHIMNEY CAP
CHIMNEY CAP
MIN CHASE ID (ROUND)
6” DIA
7” DIA
MIN CHASE ID (RECTANGULAR)
6” x 6”
7” x 7”
NOMINAL PPs FLEX LINER SIZE
80 mm
100mm
CONCENTRIC VENT/INTAKE CONNECTOR SIZE
80/125
100/150
MAXIMUM
T
O
T
A
L
VENT
LENGTH
(INLUDING PPS FLEX IN CHASE)
VENT
BWC070
51ft
BWC090
51ft
BWC120
51ft
BWC151
51ft
BWC150
47ft
BWC225
45ft
BWC300
68ft
INLET
BWC070
51ft
BWC090
51ft
BWC120
51ft
BWC151
51ft
BWC150
47ft
BWC225
45ft
BWC300
68ft
MAX CHASE HEIGHT
32ft
32ft
CROWN PPs FLEX LINER PART # (32ft COIL)
230955
230956
CROWN PPs FLEX INSTALLATION KIT PART #
230958
230959