D. Using thread tape, install the 2 10-300 into the “T” & “E” ports. Torque to 40 ft./lbs. Connect the male

end of the wire harness to the female electrical connector on the FASS pump. Reconnect the battery.
Turn key to the “On” position. With the FASS pump on, squirt a liberal amount of WD-40 or other
lubricant into the “T” port. This procedure will “wet” the Gerotor and allow for better suction during
initial priming.

Note: Do Not Put Thread Tape on Flare of Fitting

E.

Slid the FASS pump into mounting brackets with the weep hole facing down. Torque (4) bolts to 110
inch pounds.

VERY IMPORTANT: REMEMBERING THE POSITION OF THE “T” PORT, THERE IS A SMALL WEEP HOLE IN
THE BASE DIRECTLY NEXT TO THE ELECTRIC MOTOR, THIS HOLE MUST AIM DIRECTLY TO THE
GROUND!! IMPROPER INSTALLATION OF THE PUMP CAN CAUSE PREMATURE WEAR AND VOID MANU-
FACTURES WARRANTY.