background image


4. Operating Instructions

8

11/10/2010 3:19 PM

4.

O

PERATING

I

NSTRUCTIONS

Configuring the Starting Address

The Abyss™ LED 2.0

fixture uses two DMX channels. The highest channel that the fixture may

be set to in order to function properly is 511. Any address higher than this will prevent access to

all of the channels.

If this is your first time using DMX, we recommend reading the “DMX Primer” section in the

“Appendix”.

DMX Operation

This is the operating mode which will allow for control with an external DMX controller. You must
set the starting address for this mode. If this is your first time using DMX, then it is recommended
that you refer to the “DMX Primer” section in the “Appendix” of this manual.

Mode DIP

switches

DMX

1~9 = set to the DMX starting address

10 = On

Master/Slave Mode (Standalone)

This mode allows a single unit to auto change in Standalone Mode.

Turn switch to the Slave position on the slave units, and they will react the same as the Master.

The Master must be set to standalone mode.

Mode DIP

switches

Slave

1, 10 = On