DustDroid™ 600 & DustPro™ 600 HEPA Industrial Vacuums
Troubleshooting / Diagnostics
(con’t)
Failure
Possible Reasons of Failure
Corrective Action
When using the 125/250 volt
power setup one motor runs and
the other one doesn’t but when
the 120v inlet plugs are connected
directly off of a 120 volt house con-
nections they both work.
One leg of the 125/250 volt connec-
tion is loose.
Repair wiring connection on flanged 125/250
volt power connector.
When using the 125/250 volt power
setup neither motors run but when
the 120v inlet plugs are connected
directly off of a 120 volt house con-
nections they both work.
The neutral leg of 125/250 volt con-
nection is loose
Repair wiring connection on flanged 125/250
volt power connector.
Motor is not running
Circuit breaker is blown
Reset breaker
Switch is bad
Replace switch
Getting no power from power con-
nections
Check connections on all terminals
Motor is bad
Replace motor
Motor brushes need to be changed
Replace motor brushes