beautypg.com

Majestic fireplaces, Br/bc series, Common materials and factors – Vermont Casting BC36 User Manual

Page 17

background image

17

Majestic Fireplaces

®

BR/BC Series

7412944

Example of Determining Hearth Extension
Equivalents

To determine the thickness required for any new mate-
rial:

NEW

K of new material (per inch)

thickness

required

= --------------------------------------- X of listed

thickness

K of listed material (per inch)

material

Example for Common Brick

T (new) = 5.0/0.458 x 0.50 in. = 5.46 in. (new required
thickness).

WARNING: HEARTH EXTENSION MUST BE IN-
STALLED IN ACCORDANCE WITH FIGURE 23 AND
MUST NOT COVER THE BOTTOM FRONT OPENING
OF THE CIRCULATING MODEL.
Alternate noncombustible materials may be used pro-
viding the (total) thermal resistance (Rt value) of the al-
ternate material employed is greater than or equal to R
= 1.09 Thermal resistance (R) or thermal conductivity
(K), may be obtained from manufacturer of the material.
Factors are related by the formula K = 1/R. (Fig. 24)
T = given thickness
R = thermal resistance for a given thickness (T)
K = thermal conductivity
Noncombustible material with a lower R value may
be used, provided thickness of material is sufficiently
greater to maintain an equivalent (total) thermal resis-
tance (Rt).

COMMON MATERIALS AND FACTORS

MATERIAL

K*

R

MINIMUM

THICKNESS

EH2416

Common Brick

0.458

5.0

1.09 0.50 in.**

0.10 5.46 in.**

(CFM Corporation)

R Value is for 1/2 inch.

* Units of K = BTU/SQ FT/HR/˚F/IN

** Thickness of Listed Material

FP533ADD

Addendum

6/1/99 djt

8/4/99 changed .2 to .1

one inch to 1/2 inch djt

FP533ADD

Fig. 24 Hearth extension material factors.

FP550

Fig. 25 Sealing gaps.

FP550

BR/BC - SEALING

DETAILS

9/29/97

Wall Covering

Noncombustible

Decorative

Facing

Noncombustible

Decorative

Covering

Seal all cracks

between fireplace

surround and wall

materials with

noncombustible

material.

Seal crack

between fireplace

and hearth extension

with noncombustible

material.

2x4" HEADER -

Do not notch at

standoffs.

Safety Strips -

Must be overlapped

¹⁄₂

" minimum.

Hearth

Extension

Insulation

Side View