beautypg.com

Humboldt – Humboldt H-2755 Concrete Air Indicator User Manual

Page 2

background image

www.humboldtmfg.com

HUMBOLDT

Testing Equipment for

Construction Materials

Humboldt Mfg. Co.
875 Tollgate Road

Elgin, Illinois 60123 U.S.A.

U.S.A. Toll Free: 1.800.544.7220

Voice: 1.708.456.6300

Fax: 1.708.456.0137

Email: [email protected]

Table 1—Conversion Table for
Stem (Chace) Factor of 2.2

Mortar Content Multiply Stem

Ft

3

/yd

3

Reading By

10

0.81

11

0.90

12

0.98

13

1.06

14

1.14

15

1.22

16

1.30

17

1.39

18

1.47

19

1.55

20

1.63

21

1.71

22

1.79

23

1.87

24

1.95

25

2.03

26

2.12

27

2.20

Table 2—% Air Content Curve
Correction Factor

Mortar Corrected Curve Correction

Air Content %

%

1

-0.1

2

0

3

0.2

3.5

0.3

4

0.3

4.5

0.4

5

0.5

5.5

0.6

6

0.7

6.5

0.8

7

0.8

7.5

0.9

8

1.0

8.5

1.1

9

1.2

9.5

1.3

10

1.3

11

1.5

12

1.7

13

1.8