Humboldt HM-4502 Double-Ring Infiltrometer User Manual
Page 3
water fill valve that is connected to a water tank. Water enters the tank
and when filled, will eit the vent valve. At this time, close the water fill
valve. Next, close the vent valve. This seals the top of the water column.
When the ring water fill valve is opened to the ring, a vacuum forms at
the top of the water column. The constant head is maintained by a vent
tube that starts at the top vent and ends at the 0 mark on the Marriotte
Tube. Open the ring water flow valve and allow the water levels in the
double rings to stabilize and maintain a constant head. This should occur
when the water levels in the sight tubes begin to drop.
NOTE:
Leaving the fill vent valve open will cahnge the tuve into a falling
head manometer.
Test
Please refer to ASTM D-3385 for details on how to perform the test. ASTM
documents are available for sale directly from the ASTM website:
http://www.astm.org/Standard/index.shtml
Double Ring Infiltrometer with Marriotte Tubes
- H-4040 Series Water Level Indicators (4 pages)
- H-4114SD.3F Electrical Density Gauge (44 pages)
- 4000 USB Light Weight Deflectometer (96 pages)
- H-4120H Corps of Engineers Cone Penetrometer (8 pages)
- H-4137 Proctor Penetrometer Set (4 pages)
- H-4140 GeoGauge (42 pages)
- H-4166 Voluvessel (8 pages)
- H-4195 Soil Penetrometer, Pocket Style (4 pages)
- H-4200 Soil Penetrometer (4 pages)
- H-4202A Dynamic Cone Penetrometer Set (8 pages)
- H-4204 Proving Ring Penetrometer (8 pages)
- H-4210A Portable, Static Cone Penetrometer (8 pages)
- H-4212MH — Pocket Shear Vane, Metal (2 pages)
- H-4227 Vane Inspection Kit (4 pages)
- H-4385 Resistivity Meter (12 pages)
- H-4386 Soil Box (8 pages)
- HS-4210 Digital Static Cone Penetrometer (8 pages)
- H-1322B Marshall and TSR Compression Machine (12 pages)
- H-9340 Ball & Ring Demonstration (4 pages)
- H-9650 Cork Borer (4 pages)
- H-2790 Hi-Low Detector (4 pages)
- H-3220A Benkelman Beam (8 pages)
- H-1684 Flakiness Gauge for Classification of Aggregate (4 pages)
- H-1686 Void Content Apparatus for Coarse Aggregate (4 pages)
- H-2713A Specific Gravity Bench Set (8 pages)
- H-3383F Humboldt Specific Gravity Flask (Phunque Flask) (8 pages)
- H-3860A Los Angeles Abrasion Machine (8 pages)
- H-4288 Universal Sample Splitter (4 pages)
- H-4325 Sieve Shaker (4 pages)
- HP-1160 Falling Sand Abrasion Tester (4 pages)
- H-3050 Humboldt Vicat Tester (8 pages)
- H-3150 Gilmore Apparatus (4 pages)
- H-3248 Length Comparators (12 pages)
- H-3492A Organic Impurties Test Set (2 pages)
- H-3600 Cement Bleeding Apparatus (4 pages)
- H-3620 Flow Table with Mold (8 pages)
- H-3630A Water Retention Apparatus (4 pages)
- H-1021 Force Determination Adapter (12 pages)
- H-1050 Ductility Machine (8 pages)
- H-1068 Series Ductility Testing Machines (8 pages)
- H-1200 Universal and Portable Penetrometers (8 pages)
- H-1240 Electric Penetrometer with Digital Automatic Timer (8 pages)
- H-1240D Digital Penetrometer with Digital Automatic Timer (8 pages)
- H-1336D Marshall Mechanical Compactors (8 pages)