beautypg.com

Ordering information, Buffer exchange, Sample dilution troubleshooting guide – Bio-Rad Bio-Spin 6 and Micro Bio-Spin 6 Columns User Manual

Page 2: Sterilization

background image

Bio-Rad
Laboratories

Life Science
Group

Bio-Rad Laboratories Main Office,

2000 Alfred Nobel Drive, Hercules, California 94547, Ph. (510) 741-1000, Fx. (510) 741-5800

Also in:

Reagents Park, Australia, Ph. 02-9914-2800, Fx. 02-9914-2888 Wien, Austria, Ph. (1) 877 89 01, Fx. (1) 876 56 29 Nazareth, Belgium, Ph. 09-385 55 11, Fx. 09-385 65 54

Mississauga, Canada, Ph. (905) 712-2771, Fx. (905) 712-2990 Beijing, China, Ph. (01) 2046622, Fx. (01) 2051876 Copenhagen, Denmark, Ph. 39 17 9947, Fx. 39 27 1698
Espoo, Finland, Ph. 90 804 2200, Fx. 90 804 1100 Ivry sur Seine Cedex, France, Ph. (1) 49 60 68 34, Fx. (1) 46 71 24 67 München, Germany, Ph. 089 31884-0, Fx. 089 31884-100
New Delhi, India, Ph. 91-11-461-0103, Fx. 91-11-461-0765 Milano, Italy, Ph. 02-21609.1, Fx. 02-21609.399 Tokyo, Japan, Ph. 03-5811-6270

Fx. 03-5811-6272 Veenendaal,

The Netherlands, Ph. 0318-540666, Fx. 0318-542216 Auckland, New Zealand, Ph. 09-443 3099, Fx. 09-443 3097 Kowloon, Hong Kong, Ph. 7893300, Fx. 7891257 Singapore,
Ph. (65) 272-9877, Fx. (65) 273-4835 Solna, Sweden, Ph. 46 (0) 8 735 83 00, Fx 46 (0) 735 54 60 Madrid, Spain, Ph. (91) 661 70 85, Fx. (91) 661 96 98 Glattbrugg, Switzerland,
Ph. 01/809 55 55, Fx. 01/809 55 00 Hemel Hempstead, United Kingdom, Ph. 0800 181134, Fx. 01442 259118

SIG 020996 Printed in USA

Buffer Exchange

The gel in the Micro Bio-Spin columns is suspended in either
SSC buffer, pH 7.0, or Tris buffer, pH 7.4. The gel matrix is
compatible with most aqueous buffers. Buffer exchange can be
achieved using the following procedure.

1.

Follow steps 1 and 2 in the Instructions for Use section.

2.

Apply the new buffer in 500 µl aliquots. After each appli-
cation of new buffer, let the buffer drain out by gravity, or
centrifuge the column for 1 minute to remove the buffer.
Discard buffer from collection tube. Repeat as required.
Three washes result in > 99% of the buffer exchanged. Four
washes result in > 99.9% of buffer exchanged.

3.

Sample can now be applied to the column as directed in
steps 3 through 6 in the Instructions for Use section.

Centrifugation Notes

Micro Bio-Spin columns fit 1.5 ml microcentrifuge tubes for
sample collection during centrifugation. Use the 2.0 ml micro-
tubes provided with the columns for the initial column equili-
bration step.

Benchtop microcentrifuges capable of generating a minimum
force of 1,000 x (g) are suitable for Micro Bio-Spin column use.
The gravitational force created at a particular rpm is a function
of the radius of the microcentrifuge rotor. Consult the micro-
centrifuge instruction manual for conversion information from
rpm to g-force. Alternatively, to calculate the speed (rpm)
required to reach a gravitational force of 1,000 x (g), use the
following equation:

RCF (g) = (1.12 x 10

-5

)(rpm)

2

r

where r is the radius in centimeters measured from the center
of the rotor to the middle of the Micro Bio-Spin column, and
rpm is the speed of the rotor in revolutions per minute.

Sample Dilution Troubleshooting Guide

Sample dilution will occur if, during column equilibration, the
column is centrifuged without first removing the excess pack-
ing buffer. Dilution will also occur if the excess packing buffer
is left in the collection tube prior to centrifugation. The tip of
the column becomes submerged and retains excess buffer.

To correct this situation, always discard the buffer from the
collection tube after gravity draining and after the first cen-
trifugation (steps 1 and 2 of Instructions for Use section).

Sterilization

If a sterile Micro Bio-Spin column is required, autoclave the
column at 121 °C for 20–30 minutes. If exchanging buffers,
the buffer pH in the column should be in the range of 6.0 to
8.0 prior to autoclaving.

4006051 Rev B

Ordering Information

Catalog
Number

Product Description

Bio-Gel P-6 Columns in SSC

732-6200

Micro Bio-Spin 6 Column, SSC, 25, includes
25 P-6 columns in SSC buffer, 25 buffer col-
lection tubes, and instruction manual

732-6201

Micro Bio-Spin 6 Column, SSC, 100, includes
100 P-6 columns in SSC buffer, 100 buffer col-
lection tubes, and instruction manual

732-6205

Micro Bio-Spin 6 Column, SSC, 1,000,
includes 1,000 P-6 columns in SSC buffer, 1,000
buffer collection tubes, and instruction manual

Bio-Gel P-6 Columns in Tris

732-6221

Micro Bio-Spin 6 Column, Tris, 25, includes
25 P-6 columns in Tris buffer, 25 buffer collec-
tion tubes, and instruction manual

732-6222

Micro Bio-Spin 6 Column, Tris, 100, includes
100 P-6 columns in Tris buffer, 100 buffer col-
lection tubes, and instruction manual

732-6225

Micro Bio-Spin 6 Column, Tris, 1,000, includes
1,000 P-6 columns in Tris buffer, 1,000 buffer
collection tubes, and instruction manual

Bio-Gel P-30 Columns in SSC

732-6202

Micro Bio-Spin 30 Column, SSC, 25, includes
25 P-30 columns in SSC buffer, 25 buffer col-
lection tubes, and instruction manual

732-6203

Micro Bio-Spin 30 Column, SSC, 100,
includes 100 P-30 columns in SSC buffer, 100
buffer collection tubes, and instruction manual

732-6206

Micro Bio-Spin 30 Column, SSC, 1,000,
includes 1,000 P-30 columns in SSC buffer, 1,000
buffer collection tubes, and instruction manual

Bio-Gel P-30 Columns in Tris

732-6223

Micro Bio-Spin 30 Column, Tris, 25, includes
25 P-30 columns in Tris buffer, 25 buffer col-
lection tubes, and instruction manual

732-6224

Micro Bio-Spin 30 Column, Tris, 100,
includes 100 P-30 columns in Tris buffer, 100
buffer collection tubes, and instruction manual

732-6226

Micro Bio-Spin 30 Column, Tris, 1,000, includes
1,000 P-30 columns in Tris buffer, 1,000 buffer
collection tubes, and instruction manual

Empty Columns

732-6204

Empty Micro Bio-Spin Column, 100,
includes 100 empty columns, 100 buffer col-
lection tubes, and instruction manual