operation

Preperation for Starting
1. The place to set the compressor should be clean, dry and ventilated.
2. Keep the use voltage within±5% of rated.
3. Keep the oil level in the red circle leveler.

4. Recommend compressor oil use SAE30 over 10ºC, and use SAE10 below
10ºC.
5. Open the outlet valve, set the knob of pressure switch in position on (Fig.2),
let the compressor run 10 minutes with no load to ensure lubricating the moving
parts before regular service

CAUTION

Unusual noise or vibration indicates a problem. Do not continue to operate until
you identify and correct the source of the problem.

CAUTION

Do not attach air tools to open end of the hose until start-up is completed and
the unit checks out OK.

10

operation

Breather Cap

Initial Start Up

1. Pump is shipped with oil. Remove the oil cap and check pump oil

level. Add SAE 30 non-detergent pump oil (Part #4043), if neces-

sary. Hand tighten breather cap.

2. Turn pressure relief knob to engine start position.

3. The engine is shipped without oil. Refer to the engine manual for oil

capacity and viscosity recommendations.

4. Refer to engine manual to start your engine.

5. Once the engine has started, move the pressure relief knob to the

engine run position.

Engine

Start

Engine

Run

CAUTION

Unusual noise or vibration indicates a problem. Do not continue to

operate until you identify and correct the source of the problem.

CAUTION

Do not attach air tools to open end of the hose until start-up is

completed and the unit checks out OK.

6. Run the unit for 30 minutes, with ball valve open, to break in pump

parts.

7. Close the ball valve to shut off airflow. The compressor is now ready

for use.

8. After 50 hours of operation change the compressor oil.

FIG. 2

ON/OFF

DISCHARGE VALVE 2

DISCHARGE VALVE 1

FIG. 1

KNOB

SAFETY VALVE