Basement Watchdog BWSS Series User Manual
Important safety instructions, Items included, You may also need

Specifications
1/2 HP Model BWT050
3/4 HP Model BWT075
GPH @ 0’
4100
5300
GPH @ 10’
2770
3630
Pump diameter
7.375”
9.75”
Volts
115V, 60Hz
115V, 60Hz
Amps
3.8
4.8
Important Safety Instructions
SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and
OPERATING INSTRUCTIONS for the Basement Watchdog pumps. You will need to refer to
it before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.
• ALWAYS disconnect the pump from the power source before servicing or making
adjustments.
• NEVER handle the pump or motor with wet hands or when standing on a wet or damp
surface while the pump is plugged into the power source.
• MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is
wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain that
it is only connected to a properly grounded, 3-prong receptacle. If you have a 2-prong
receptacle, have a licensed electrician replace it with a 3-prong receptacle according to
local codes and ordinances.
• NEVER bypass grounding wires or remove the ground prong from the plug.
• DO NOT use an extension cord. The electrical outlet should be within the length of the
pump’s power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.
• DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid
kinking the cord.
• MAKE SURE the supply circuit has a fuse or circuit breaker rated to handle the power
requirements noted on the nameplate of the pump.
• DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.
• DO NOT expose the control unit to rain or snow.
• DO NOT operate the pump or control unit if it has been damaged in any way.
• DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.
• DO NOT disassemble the pump or control unit. When service is required, contact
Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:
Glentronics, Inc.
645 Heathrow Drive, Lincolnshire, IL 60069
ƽ CAUTION
ƽ WARNING
Risk of electric shock. To reduce this risk, observe the
following precautions.
To reduce the risk of hazards that can cause injury or
property damage, observe the following precautions.
Basement Watchdog
Sump Pumps
Instruction Manual &
Safety Warnings
Items included:
Pump
Dual float and controller
Stainless steel hose clamp
2" x 1-1/2" reducer adapter
(on 3/4 HP pump only)
You may also need:
1-1/2” or 2" rigid PVC pipe to
connect to the existing plumbing
A check valve or union
PVC pipe cleaner and cement
The Dual Float
& Controller
3/4 HP Pump
BWT075
1/2 HP Pump
BWT050
Note:
The 3/4 HP pump will accomodate a 2" discharge pipe. However, most
homes have 1-1/2" pipes. Therefore we have included a 2" x 1-1/2"
reducer adapter with this pump. You may replace your 1-1/2" discharge
pipe with a 2" discharge pipe, and a 2" adapter to obtain the optimum
gallons per hour.
1-1/2”
discharge
2”
discharge