Aphex Remote Pre Parametric MIDI Commands
Command
Control
Value Range
00h
Input Gain
1Ah to 41h (26 to 65)
01h
Main Max Out
00h to 1Bh (0 to 27)
02h
Aux Max Out
00h to 1Bh (0 to 27)
03h
Phantom Power
00h = OFF, 01h = ON
04h
Low Cut Filter
00h = OFF, 01h = ON
05h
Limiter (MicLim)
00h = OFF, 01h = ON
06h
Polarity Reverse
00h = OFF, 01h = ON
07h
Mute
00h = OFF, 01h = ON
08h
Pad
00h = OFF, 01h = ON
0Ah
Test Tone -20dB
00h = OFF, 01h = ON
0Bh
Test Tone 0dB
00h = OFF, 01h = ON
17h
Test Tone (alternative method)
00h = OFF, 01h = -20dB, 02h = 0dB
20h
Request Parameter SysEx Dump
01h (required)
56h
Request Extended SysEx Dump
00h (any value placeholder byte)
F0 00 00 38 xx xx
xx xx xx
F7
SysEx Start
MIDI Channel
MIDI Device
xx
Net Number
Command
Mic Channel
Va
lue
xx xx xx
Command
Mic Channel
Va
lue
xx xx xx
Command
Mic Channel
Va
lue
SysEx End
Put 1 to 64 3-byte Commands Here
Aphex MIDI I.D.
System Exclusive (SysEx) Parametric Control String
The Model 5200, will allow you to control your
Aphex 1788A or 188 from any MIDI controller. You
will need to be familiar be with the programming of
your MIDI device.