beautypg.com

Maintenance & lubrication record – Great Plains 2520 Operator Manual User Manual

Page 13

background image

-

11

8/16/06

Great Plains Mfg., Inc.

Section 4 Troubleshooting

Folding No-Till Seed Box Agitator 118-591M

Section 3

Maintenance & Lubrication

Section 4

Troubleshooting

Maintenance & Lubrication Record

Item to be Serviced

When to Perform

Reference

Date

Problem

Solution

Uneven metering

Check for plugging in metering cup.

Check to see if seed tubes are plugged.

Reduce ground speed.

Check for lumps or trash in the material. Screen these out if needed.

Check all drive chains, sprockets, keys and pins.

The agitator will not guarantee perfect seeding of trashy, wet or sticky material.

Actual metering rate is different than
desired

Check tire pressure. Proper inflation is listed in the “Tire Inflation Chart", Section
2, page 4.

Check gauge wheel size. Proper size is 11L x 15".

Seed box not emptying evenly

Some sections of the box have more metering cups causing that section to run out
first.

This manual is related to the following products: