beautypg.com

Great Plains YP4025-2420 24 Row 20-Inch Quick Start User Manual

Quick setup guide for intelliag model yp40 20, Step 1: pre-programming preparation, Step 4: row status/row width setup

background image

Quick Setup Guide for IntelliAg Model YP40 20”

11001-1532-200909

©2009 DICKEY-john Corporation
Specifi cations subject to change without notice.

STEP 1: Pre-Programming Preparation:

Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings.
If errors are detected (e.g., failed sensors, incorrect confi guration) an alarm and code displays. Alarms are silenced by pressing the Alarm Cancel button

. Refer to Operator’s

manual for troubleshooting assistance.
The system has three user levels. The system loads in User Level 1 (operator level) at every power cycle. Access to User Level 2 and 3 screens to setup constants (system confi gura-
tion) requires a password.

1.
2.

3.

The Quick Setup Guide assumes the Virtual Terminal, Master Switch, Working Set Master Module,

Working Set Member Module, and all sensors have been connected and properly installed. Refer-

ence Operator’s manual for installation instructions. NOTE: The master switch is only required for

hydraulic control systems. Reference the manual for instructions to assign a master switch

as an auxiliary input.

STEP 3: Auto Confi guration (Identifi es sensors connected to each module)

Auto confi g is performed at the factory, but may need to be done in the fi eld as changes
are made to the system or if options are added to the base planter.

Verify Auto Confi g results are correct. Check that the correct number of rows are assigned
to the correct module and number of hopper sensors are assigned accurately.

To Run Auto Confi g:

Press the Next Page button

until the Module Confi guration button appears.

Press the Module Confi guration button

.

Press the AUTO CONFIG button

.

Hour glass will indicate system is being confi gured detecting the presence of seed or hopper
sensors connected to each module and will be automatically assigned to the appropriate
module.
When Auto Confi g completes, press the Row Assign button

to display the Row

Assignment screen to verify correct Row # is assigned to the correct module based on serial
number.
Enter # of rows assigned to each module.

1.

1.
2.
3.
4.

5.

6.

STEP 5: Material Confi guration Setup (Controlled Hydraulic Drive)

16 different materials can be confi gured for use as planter controls. Reference the System
Confi guration section in the Operator’s manual for additional information.

At the Main Menu screen, press the Control Setup button

.

Select and press one of the Material buttons (Material 1-16).
Enter desired values from Table B.
Press the Control Setup button

to return to the Control Setup screen.

Repeat steps 2-4 for additional materials.
Press the Channel Setup button

to proceed to channel setup screen.

1.
2.
3.
4.
5.
6.

TABLE B:

Material Setup

Default Value/

Value to Enter

Controlled Hydraulic Drive

Instructions/Defi nitions

Matrl Label

Matrl 1

Material Name can be customized to accurately defi ne

the material’s type. Creating a name allows for quick

identifi cation at the Control Setup screen.

Type

Planter Control

Desired type of application control channel being used

for a specifi c material. The Material Type must correctly

match the Control Type to be able to select Material from

the Material Summary screen and operate properly.

Units

Ks/Ac

S/Sec

Automatically changes with the type of material applica-

tion selected. Changes units for target application.

Preset Method

Enable

Enabled Preset Method allows 10 user-defi ned target

rates to be adjusted from the Main Work screen using Inc

or Dec buttons. A Disabled Preset Method increases/de-

creases the target rate based on the % values set at the

Material Setup screen.

Seeds per Rev

See Manual

Set to number of seeds per 1 disc revolution.

Disc Low Limit

(Singulator Plus)

5

Set to desired min seed disc RPM.

Disc Low Limit

(Precision Finger)

40

Set to desired min seed disc RPM.

Disc High Limit

(Singulator Plus)

40

Set to desired max seed disc RPM.

Disc High Limit

(Precision Finger)

85

Set to desired max seed disc RPM.

High Pop Alarm

15%

This is the percentage above the target population of

the planter channel if rows are assigned to the planter

channel. If rows are not assigned to a planter, this is

the percentage above average planter population for all

unassigned rows.

Low Pop Alarm

15%

This is the percentage below the target population of the

planter channel if rows are assigned to the planter chan-

nel. If rows are not assigned to a planter channel, this is

the percentage below average planter population for all

unassigned rows.

Product Level

Alarm

Sets the level to trigger an alarm alerting of low product

levels. Entered value is an estimate in volume.

Row Fail Rate

2/1 (2 seeds

every 1 second)

Set to desired number of seeds per second to trigger

seed sensor failure alarm.

STEP 4: Row Status/Row Width Setup

At the Row Assignment screen, press the Row I/O button

.

Begin entering desired values using Table A as reference.
Press the Work Screen button

when Row Status/Row Width confi gurations are

complete to return to the Main Work screen.

1.
2.
3.

TABLE A: Row

Status/Row

Width Setup

Default Value

or Value to

Enter

Instructions/Defi nitions

Row Width

20”

Enter row width distance in inches to calculate seed rate

correctly. NOTE: Using 15” planter in 30” mode should

change On/Off Pattern to Every 2nd Row Off.

Auto Update Width

Enabled

When enabled, implement width will automatically calcu-

late. If disabled, manually enter implement width.

On/Off Pattern

Every Row On

On/Off Pattern indicates specifi c row patterns to be on

or off. Select pre-defi ned planter All Row On pattern.

For other pre-defi ned planter patterns or individual row

settings, reference Operator’s manual.

Pop/Block Pattern

Every Row

Population

Determines which sensors are used to calculate popula-

tion and those used only for blockage detection. Select

pre-defi ned Every Row Population. For other pre-defi ned

patterns, reference Operator’s manual.

1

STEP 2: Change User Level to Dealer Level

To change the user level, a 6-digit password is required. Password includes the fi ve-digit
serial number found on the label of the Working Set Master or Information screen.

On the IntelliAg Main Work screen, press the Diagnostics button

.

At the Diagnostics screen, press the Information button

.

At the Information screen, record serial number of WSMT.
Press the Password button

.

On the Password screen, enter the 6 digit password as follows: enter the fi rst digit as 2 for
User Level 2. For the next fi ve digits, enter the Working Set Master serial number taken
from the WSMT or Information screen.
Press the OK button

. “Dealer screens on” appears at the bottom of screen confi rm-

ing the password and dealer screens are activated.
Press the Work Screen button to return to the Main Work screen.

1.
2.
3.
4.
5.

6.

7.

S E R I A L
N U M B E R

1

M O D U L E
T Y P E

M O D U L E
A D D R .

WSMB-POM
WSMB-POM

2

WSMB-18R

3

10001

10001
10002

WSMT-GY

10001

4

# O F

R O W S

MODULE

ADDR.

TYPE

R O W

# ’s

9 - 1 6

1

WSMB-18R

2

WSMT- GY

8

8

1- 8

3

WSMB-18R

8

1 7 - 2 4

Module Configuration Screen

Seed Sensor Configuration Screen

10002
10003

10001

WSMB-18R
WSMB-POM
WSMB-CFM

5
6
7

(Optional)

(Optional)