Warning, Hydraulic hose hookup, Bleed the hydraulics – Great Plains NTA3010 Operator Manual User Manual
Page 13

11
Section 1 Preparation and Setup
8/14/
NTA3010 and NTA3510 Air Drill Implement SN Z1370- 160-219M
Great Plains Mfg., Inc.
Hydraulic Hose Hookup
!
WARNING!
Escaping fluid under pressure can have sufficient pressure to
penetrate the skin causing serious injury. Avoid the hazard by
relieving pressure before disconnecting hydraulic lines. Use a
piece of paper or cardboard, NOT BODY PARTS, to check for
leaks. Wear protective gloves and safety glasses or goggles
when working with hydraulic systems. If an accident occurs, see
a doctor immediately. Any fluid injected into the skin must be
surgically removed within a few hours or gangrene will result.
Great Plains hydraulic hoses are color coded to help you
connect hoses to your tractor outlets.
To distinguish hoses on the same hydraulic circuit, refer to
plastic hose holders. See Figure 1-3. Hoses under the ex-
tended-cylinder symbol feed cylinder base ends. Hoses
under retracted-cylinder symbol feed cylinder rod ends.
Figure 1-3
Hydraulic Hose Label
Connect implement hydraulic hoses to quick couplers on
rear of cart. See Figure 1-4.
Figure 1-4
Hose Connections
Color Tie
Hydraulic Function
Blue
Lift Cylinders
Yellow
Air Drill Fan and Fold Cylinders
17641
17189
Serial Numbers Z1100 and Earlier
Working left to right, hook hoses to cart as follows.
a.
markers
b.
markers
c.
rod-end lift (1/2-inch hose)
d.
base-end lift (1/2-inch hose)
e.
rod-end fold (3/8 inch hose)
f.
base-end fold (3/8-inch hose)
Serial Numbers Z1101 and Later
Working left to right, hook hoses to cart as follows.
a.
Hook either marker hose to outlet A.
b.
Hook remaining marker hose to outlet B.
c.
Hook retracted blue (rod-end lift) to outlet C.
d.
Hook extended blue (base-end lift) to outlet D.
e.
Hook retracted yellow (rod-end fold) to outlet E.
f.
Hook extended yellow (base-end fold) to outlet F.
(See Figure 1-5.)
g.
Hook decaled sump hose to outlet G. (See Figure
1-5.)
Figure 1-5
Fold Hoses, Serial Numbers Z1101 and Later
NOTE: SAE O-ring and JIC 37˚ flare-type hose connec-
tions do not require sealant or high torque for a good seal.
Carefully check all hoses to make sure none will be dam-
aged by implement operation. Reroute hoses or use cable
ties to keep hoses in a safe place.
Bleed the Hydraulics
To function properly, the hydraulics must be free of air. If
the hydraulics have not been bled, the implement will fold
in jerky, uneven motions or some frame sections will run
higher than others. If the hydraulics were not bled during
initial implement setup or if you replace a part in the hy-
draulic system during the life of the drill, complete the fol-
lowing procedures.
17256
F