12. If the screen reads TIME TOO LOW or TIME
TOO HIGH, you will need to change the amount
of seed that you will count or measure. For cali-
bration accuracy, the Controller firmware will not
allow you to calibrate at settings that would re-
sult in the drive rotating for less than 4 seconds
or more than 255 seconds. Press Function key
to advance to next window.
Refer to Figure 11
!
WARNING
The drive is about to operate. There is a danger of entan-
glement if anyone is in the drive area. Be sure to verify
that no one is near the drive area before advancing to the
next step.
Refer to Figure 12
13. Only after you have verified the drive area is
clear, press the Up arrow key to initiate calibra-
tion mode. If drive area isn’t clear, press Down
arrow key to exit calibration mode.