Great Plains 3N-30P Assembly Instructions User Manual
Page 8
196-264m
4/8/2004
Great Plains Mfg., Inc.
Monitor Systems Option
8
Refer to Figure 1
1.
Assemble mounting bracket (1) and sensor
bracket (2) together using hardware supplied
in kit. Assemble mounting bracket to the in-
side of the plate on the left gauge wheel. In-
stall the Dickey-john magnetic pickup sensor
(3) to the sensor mounting bracket.
2.
Loosen fasteners at bearings (4) on either
side of the contact wheel pivot shaft (5). Slide
pickup disk (6) onto shaft using lock collars (7)
on either side to hold in place.
Refer to Figure 2
3.
Tighten bearings back down. Align sensor
and pickup disk with centerline. Be sure to
tighten set screws after alignment is done.
4.
Connect sensor to wire harness sensor ex-
tension.
5.
Set initial distance between sensor and pick-
up disk at 0.040 inch. This may need to be ad-
justed up or down as necessary.
6.
Figure 3 shows routing for wire harness.
Refer to the DICKEY-john Installation and
Operating Manual for further instructions.
19284
Figure 3
Routing of Wire Harness
Figure 2
Centerline
19286
Figure 1
Templates for 833-232C 7 1/2 Row Spacing Material Flow Module