Warning, Specifications, Unpacking – Chicago Electric 6-1/2 Gallon Plastic Parts Washer 96952 User Manual
Page 8: Operating instructions

Page 8
SKU 96952
For technical questions, please call 1-800-444-3353.
speciFications
Electrical Requirements
120 V~ / 60 Hz / 0.27A
Maximum Flow
317 Gallons per Hour
Power Cord
18AWGX3C
unpacKing
When unpacking, check to make sure that the item is intact and undamaged. If
any parts are missing or broken, please call Harbor Freight Tools at the number shown
on the cover of this manual as soon as possible.
operating instructions
read the entire iMportant saFetY inForMation section at the
beginning of this manual including all text under subheadings therein
before set up or use of this product.
warning
Do not use any highly volatile, flammable or
combustible solvents, or fuels such as gasoline, diesel, or toluene. use
only non-corrosive water based solvents.
warning
Parts being cleaned may contain and leave flammable
or combustible residue or fluids in the Parts Washer. Check for solvent
fumes to verify nonflammability and non-toxicity. Use in a well ventilated
area. do not smoke. always dispose of solvents properly.
Place the Parts Washer in a well ventilated area on a surface capable of bearing
1.
the combined weight of the unit, solvent, and parts.
Read all manufacturer directions for the solvent and follow the guidelines for use.
2.
Add the correct solvent for the application at hand until the Pump (3) is entirely
3.
submerged.
Carefully place the Shelf (2) into the Solvent Bin, and place the parts to be
4.
cleaned on the Shelf (2).
Plug the Parts Washer into a grounded 120V electrical outlet. Wearing protective
5.
gear, turn the Power Switch on, and direct the Spigot (1) to clean the products.
warning
this parts washer is intended for use only as a plastic
(polystyrene) parts cleaner only. do not use this product to clean other ma-
terials. solvents used to clean other materials could chemically react with
the components of this machine and cause an explosion.
REV 08j