Technical Data
H
i
F
lo
™ Ro-M
obile
Reverse osmosis
3. Technical Data
3.1. Scope of delivery
RO30G & C
RO60S
Electrical connection, primary
230 V/50 Hz
Inlet pressure
0-6 bar
Max. operating pressure
10 bar
Suction capacity (with 1“ line, 15°C)
5m/-0,5 bar
Yield
ca. 60 %
Water temperature
5°C-25°C
Required power
at 15°C
Salinity in raw water
max. 1000 mg/l
Salt retention rate
100% (resin filter)
Blocking index
max. 3
SiO2 content in raw water
20 mg/l
Permeate output at 15°C water temperature l/h
300-350l
650-710l
Pump connection
0,75 kW
1,1 kW
Standard feed water connection
G3/4“
1“
Standard concentrate connection
G3/4“
Standard permeate connection
G3/4“
Height
1230 mm
1230 mm
Width
580 mm
750 mm
Depth
510 mm
510 mm
Weight
app. kg 55 app.. 73 kg
1. Robust trolleyl
2. Water supply connection
3. RO30G: 2,5“x 10“ Standard-Pre-filter
RO30C: 4,5“ x 10“ Carbon-Pre-filter (Chlorine)
RO60S: 4,5“ x 10“ Standard-Pre-filter
4.
Pressure gauge water inlet downstream pre-filter
5. RO30G&C: Main membrane
RO60S: Doublemembrane
6.
RO30G & C: 4,5“ x 20“ Secondary resin filter
RO60S: 4,5“ x 20“ Carbon-Pre-filter (Chlorine)
7. Concentrate outlet
8. Pump control system
9. Permeate outlet
10. Pump
11. TDS-meter
12. Pressure indicator, pump
13. Pressure relief valve
•
Filter wrench, pre-filter (small)
•
Filter wrench, pre-filter (large)
•
Feed pipe for preservation