beautypg.com

Installation, Electrical requirements, Electrical connections – Creda D130E User Manual

Page 25

background image

ELECTRICAL REQUIREMENTS

For your own safety, we recommend that your cooker is installed by a competent
person such as one who is registered with NICEIC (National Inspection Council for
Electrical Installation Contracting). The cooker should be installed in
accordance with the latest edition of the IEE Regulations.

Warning: This appliance must be earthed.

ELECTRICAL CONNECTIONS

The installer must check that the voltage shown at the rating plate corresponds with
the house electricity supply.
The oven must be supplied via a suitable double pole isolating switch, having a
contact separation of at least 3mm in all poles placed in a readily accessible
position adjacent to the unit.
If the oven is to be wired into a connector unit, this may be positioned behind the
oven providing the following requirements are met:
i) The connector unit must not project from the wall more than 25mm.
ii) The top of the connector must not be more than 350mm above the base of the
oven recess.

Remove the terminal cover at the rear base of the oven. Pass the cable through the
cable clamp and connect to the appropriate terminals provided.
Allow sufficient cable so that the oven can be set down on the floor whilst still
connected.
Tighten the screws on the cable clamp and replace the terminal cover.
Make main connections.
This appliance conforms to B.S. EN 55014 regarding suppression of Radio and
Television reception interference.
Where a double oven is used, a 20 amp Double Pole control switch should be used
to feed the unit using a suitable rated cable.
Where a hob is fitted adjacent to an oven, a 45 amp Double Pole control switch
should be used to feed both units via separate suitably rated cables.
We recommend a minimum of 4mm

2

PVC insulated twin and earth cable

conforming to B.S. 6004 for connection of each appliance.

This appliance must not be installed over any other appliance that generates heat.

Installation

25

Note: Due to many different types of installation, a mains cable is not supplied with this

product. The installer will fit the correct type and length of cable