QUANTUM DI HEATER OPERATION / MAINTENANCE MANUAL

PAGE 13

3

INSTALLATION

3.1 UNPACKING

Remove heater system from crate and inspect heater cabinet for any
signs of damage (dented panels, paint scratches, etc.). Shock indicators
on the heater cabinet should be checked for rough handling during
shipment. Any damage to the system should be reported to the carrier
immediately.

Front door keys are not shipped with the system. Keys are available
upon request. (Key, Handle, 'L' LOC, [PROLINE] #98003360/B).

CAUTION: Heavy Object. When lifting or moving the system,

follow safe heavy object handling methods to prevent injury.

Be careful to not damage the drain fitting located under the heater
cabinet when using a dolly or forklift.

3.2 LOCATION

Locate the heater near the point-of-use to reduce plumbing heat loss.
Access to the front and rear of the system will be necessary for
maintenance and hook-up.

3.3 HOOK-UP

All utility hook-ups associated with the DI water heater are easily
accessible and are referenced in the Appendix.

After positioning heater at operating location, adjust the four leveling feet
until the heater is level and stable.

Connect the cold DI supply line to the “Cold DI Inlet” connection.

Connect the hot DI process lines to the “Hot DI Outlet” connection.
Use only hot DI compatible plumbing components. They must be
rated at a minimum of 110°C (230°F) and 414kPa (60 psig).

NOTE: It is recommended that the hot water supply line have a bleed, or
purge, at the point-of-use to reduce the possibility of the DI water
becoming stagnated in the heaters when not in use. The amount of this
bleed is best evaluated on a case-by-case basis, taking into account
each user’s criteria and production standards.