SS40 SURGE OPERATION / MAINTENANCE MANUAL
2.4 PARTS LIST
ILL
NO
PART NO
QTY
DESCRIPTION
MATERIAL
1
AT021
1
Union Nut
PP
2
98003750
2
3/4” Pillar Super 300 Nut
PFA
3
98003752
1
Pillar Super 300 Insert
PFA
4
AT022
1
Fluid Chamber, Inline
PTFE
5
AT002
1
Diaphragm
PTFE
6
AT006
1
Push Plate
PTFE
7
AT005
1
Pilot Boss
PP
8
AT007
1
Shaft
PFA
9
AT013
1
Pilot Valve Assembly
PTFE / PFA
10
C0082
1
Seal
PTFE
11
AT003
1
Air Chamber
PP
12
98003396
1
3/8” Male Connector
PP
13
AT019
1
Mounting Bracket
PP
14
98003207
2
Screw
PP
2.5 CLEAN-UP
The SS40-X Surge Suppressor may be flushed clean with either DI water or a
rinse tank for 10 to 15 minutes.
2.6 DISASSEMBLY
During the life of the Surge Suppressor it may be necessary to perform certain
preventative maintenance procedures to ensure its continued high performance.
This Section and Section 2.7
Assembly are provided for the user’s convenience
in disassembling and re-assembling the surge suppressor.
Thoroughly clean and flush the suppressor and pump before disassembly if
possible using DI water.
Disconnect suppressor air supply line from suppressor.
Rotate suppressor CCW (counter-clockwise) to remove suppressor from
pump and place in containment bag.
Decontaminate both exterior and fluid chamber of suppressor using DI water.
Remove any air fittings from supply and exhaust ports of the suppressor
body.
Clamp suppressor in vise to hold body with fluid connection pointing up.
Using strap wrench and 1/2” torque wrench driver, remove union nut turning
it CCW to loosen.
Remove union nut carefully. Watch threads for possible entrapment of
spilled chemical.
Remove suppressor head noting clocked position of 1/16” diameter locating
mark on head for reassembly.
Remove diaphragms for inspection.
Flush body with DI water and dry to remove any possible contamination.
Connect suppressor supply port to 20-psig air supply and test pilot valve for
leakage and actuation. Replace if escaping air can be heard or valve will not
discharge when depressed.