5 parts list, 6 clean-up, 7 disassembly – Trebor 110R User Manual
Page 14

PAGE 14
MODEL 110R PUMP OPERATION / MAINTENANCE MANUAL
4.5 PARTS LIST
ILL
NO
PART NO
QTY
DESCRIPTION
PM
YEAR #
MATERIAL
1
J0092
1
Body
PTFE
2
1110B0012
2
Suction Sleeve
PTFE
3
98002318
4
O-Ring, PTFE Check Valve
2
PTFE
4
J0097
4
Check Ball
2
PFA
5
1110B0013
2
Discharge Sleeve
PTFE
6
J0100
2
Seal, Check Bore Cap
2
PTFE
7
J0101
2
Check Bore Cap
PTFE
8
98001167
2
Shaft Seal
2
PTFE
9
1110A0035
1
Shaft
2
PFA
10
J0093
2
Push Plate
PTFE
11
J0090
2
Diaphragm Set
2
PFA
12
98001423
2
Main Seal
2
Viton
13
1110B0015
6
Tie Bolt Assembly
SS416, PFA
14
1110D0011-01
1
Slave Head
PP
15
11001220
2
Pilot Valve
Brass, SS,
NBR
16
1110A0022
2
Main Transfer Tube
PFA
17
98002332
2
O-Ring, Transfer Tube
2
Viton
18
1110A0023
1
Pilot Transfer Tube
PFA
19
98002331
2
O-Ring, Transfer Tube
2
Viton
20
AM022
1
Mounting Base
PP
21
98003207
4
Mounting Screw
PP
22
98003071
1
Locking Lever Screw
PP
23
AM023
1
Locking Lever
PP
24
C0102
1
Quick Release Base
PP
25
1100C0026
1
Shuttle Plug
PP
26
11001230
1
Detent
1 & 2
Acetal, SS
27
11001210
1
Shuttle Assembly
1 & 2
SS410, Buna
28
C0135
1
Check Muffler Assembly
2
PP, NPRN
29
98001109
12
Tie Bolt Cap
2
PU
30
98002338
6
Nut, Flanged
SS18-8
31
1110D0010-01
1
Master Head
PP
4.6 CLEAN-UP
The pump fluid cavities may be flushed clean by cycling with the suction (IN) and
discharge (OUT) lines connected to a DI water flushing or rinsing tank. Flushing
using an external pressure source without allowing the pump to cycle will result in
incomplete removal of potentially dangerous chemicals.
NOTE: To effectively eliminate chemical contamination, the pump should cycle
for 10-15 minutes using the flushing DI water as described above.
4.7 DISASSEMBLY
During the life of the pump it will be necessary to perform certain preventative
maintenance procedures to ensure continued high performance operation. This
section and the next (4.8
Assembly) are provided for the user’s convenience in
disassembly and re-assembly procedures.
Thoroughly clean / flush the pump using DI water (Refer to Section 4.6
Clean-Up).
Unlock pump from quick release base by pulling out locking lever on front of
base. Then slide pump forward until it stops. Lift pump off base.
Remove check muffler assembly.