Eghst4(x)b - black – SoundOff Signal GHOST Surface Mount w (10-30 vdc) Permanent Mount Bracket User Manual
Page 2

EGHST4(xx) 07.14
NOTE: The GHOST is equipped with flash pattern memory. Once you
have selected a pattern the GHOST will always activate to that
pattern every time the unit is turned on. Tape up and secure WHITE
wire so that it will not accidentally change your selected pattern.
Ghost Sync Configuration Instructions
IMPORTANT! A MAXIMUM OF 4 SINGLE LIGHTS
CAN BE SYNCED TOGETHER
1. Set ID#
a. Identify which pattern and sequence you want and look up
ID# settings at left.
b. Connections
i. RED:
+10-30Vdc
ii. WHT: +10-30Vdc (Note: you will need to disconnect after
power is applied)
iii.
BLK:
Ground
c. Apply power to unit
d. Without disconnecting power from unit, disconnect WHT wire
e. Momentarily connect WHT to Ground to change ID #
i. Identify ID# by number of sequential flashes
ii. Possible ID#s: 1 – 4
f. Disconnect power from unit to get out of ID mode.
2. Set Pattern
a. Reapply power to units.
b. Once all Light Head ID#s are configured, make sure all
lights are flashing the same pattern.
c. Connect corresponding colored wires of all units together:
RED to RED, etc.
d. Change Pattern
i. Momentarily connect WHT wires to Ground
ii. Observe pattern change on all lights connected
e. Insulate all wires by taping with electrical tape
3. Connect Master Switch for Application
a. IMPORTANT! Ensure WHT Pattern/Sync Wires are tied
together
PATTERN RESET
1. Remove power
2. Place WHITE (sync) wire to ground
3. With sync wire grounded, re-power RED wire
4. Maintain for one second (light will dim)
5. Remove power and ground (pattern 1 set)
SLAVE MODE
The GHOST is capable of being activated through the use of a user
supplied flasher by putting it in slave mode.
1. Permanently connect the GHOST WHITE and BLACK wire to a
good, convenient ground.
2. Connect the GHOST RED wire, through a 5Amp fuse, to the output
of a +10-30Vdc switching flasher.
2 SINGLE LIGHTS
Follow the ID selection steps and set the GHOST to the following
ID:
IMPORTANT: Make sure both lights flash the same pattern!
- Both assemblies simultaneous with individual lights alternating.
- Example: Driver/Passenger sim; Dr. (left alt right)
Pass. (left alt right)
- Set both GHOST Assemblies to ID#1
- Both assys. alternating with individual lights alternating.
- EX: Dr./Pass. alt; Dr. (left. alt. right.) Pass. (right alt. left)
- Set one GHOST to ID#1 and the other to ID#3
- Both assys. alternating with individual lights simultaneous
- EX: Dr./Pass. alt; Dr. (left sim left) Pass. (right sim right)
- Set one GHOST to ID#2 and the other to ID#4
- Both assys. simultaneous with individual lights simultaneous.
- EX: Dr./Dr. sim; Dr. (left sim left) Pass. (right sim right)
- Set both Ghost housings to ID#2
X-PATTERN - To obtain X-Patterns, follow the ID SELECTION
steps and set one of the four GHOST lights to ID#1, one to ID#2,
one to ID#3, and one to ID#4. Then proceed to the PATTERN
SELECTION steps.
NOTE: Be sure to mount each GHOST in the correct placement
based on ID#.
PATTERN SELECTION
1. Disconnect WHITE wire from any connections if applicable.
2. Turn GHOST ON.
3. Momentarily touching and removing the WHITE wire(s) to
ground will advance the GHOST to the next flash pattern.
Touching and removing the White wire for more than a few
seconds will allow you to change the GHOST to the previous
pattern. See flash pattern table. Continuing to touch and
remove the WHITE wire(s) to ground will allow you to scroll
through the pattern list. After pattern #33 is reached the list
will start over again at pattern #1.
X-Pattern Light Head Placement
ID#4 ID#2
ID#3 ID#1
X-Pattern Sequence
ID#1> ID#4> ID#2> ID#3
Flash Patterns
Pattern Name
1 Light
Alternating 2
Lights
Silmultaneous 2
Lights
X-Pattern
4 Lights
F.P.M.
(Flashes /
Minute)
1. Quint
x
x
x
70
2. Warp
x
x
x
350
3. Inter-Cycle Flash
x
x
4. Double Flash
x
x
x
70
5. Quad Flash
x
x
x
80
6. PowerPulse
x
x
x
180
7. RoadRunner
x
x
x
113
8. Q-Switch
x
x
9. RoadRunner Steady
Burn
x
x
113
10. Quad Steady Burn
x
x
80
11. E-Ideal Single Flash
x
x
x
200
12. E-Ideal Double
Flash
x
x
x
146
13. Quad2 Flash
x
x
x
67
14. Double2 Flash
x
x
x
95
15. X-Warp
x
16. X-Double
x
17. PowerRunner
x
x
x
18. LCR Quint
x
x
x
19. Warp
3
x
x
x
20. Ultra Warp
x
x
x
545
21. Thunder &
Lightning
x
x
22. Lite Speed
x
x
x
85
23. SuperSonic
x
x
170
24. LCR Lite Speed
x
x
x
25. SuperSonic Ultra
x
x
x
26. Tempo Shift
x
x
x
27. Tempo Shift Warp
x
x
x
28. SBE2
x
x
x
67
29. C
2
x
x
x
200
30. U
2
x
x
x
176
31. Ultra Glow
x
x
x
32. Cyclone
x
x
x
33. Chameleon
x
x
x
GHOST® SINGLE SURFACE
MOUNT LIGHT W/ PERMANENT
MOUNT BRACKET
EGHST4(x)B - Black