beautypg.com

Sky-Watcher SynScan V4 Hand Controller User Manual

Page 14

background image

14

4.

Now the screen will display “

Point scope to RR ZZ.Z’ TT.T’

”, which means point the telescope

to RR region, the exact azimuth is ZZ.Z degree and the exact altitude is TT.T degree. Users

can use the direction keys on the SynScan hand control to move the mount and point the

telescope to the 1

st

alignment star selected in the previous step. Center the 1

st

alignment

star in the FOV of the finder scope or the red dot finder, and then press

ENTER

key to pro-

ceed to the next step.

PART III : ALIGNMENT

5.

Now the screen will display “

Ctr. to eyepiece..

” and the name of the selected 1

st

alignment

star. The star should have been in the FOV of the telescope. User can use the direction

keys to center it in the eyepiece and then press the

ENTER

key to proceed to the next step.

Aligning the 2

nd

Star:

Cancellation During Aligning Process:

1.

If the 1

st

alignment star is not a planet, the LCD screen will display “

Choose 2

nd

Star

”; other-

wise, it will display “

Choose 1

st

Star

”.

2.

Use the scrolling keys to browse through a list of star names and press

ENTER

key to pick

the one on the screen as the 2

nd

alignment star. The mount will then automatically slew and

point the telescope towards the 2

nd

alignment star in the sky.

3.

After the mount stops, the hand control will display the name of the selected 1st star on line
1 and “Ctr. to eyepiece..“ on line 2. Now the telescope should point rather closely to the 2

nd

alignment star (generally, in the FOV of the finder scope).

4.

Now users can use the direction keys to move the telescope to align with the 2

nd

alignment

star. That is, center the 2

nd

alignment star in the FOV of the finder scope, and then center

it in the FOV of the telescope’s eyepiece. Press

ENTER

key to confirm the centering of the

star and proceed to the next step. Generally, users can use Rate 5 or 6 to center the star

in finder scope and use Rate 2 or 3 to center the star in the telescope’s eyepiece.

5.

If the 1

st

alignment star is not a planet, the SynScan hand control will now display “

Align-

ment Successful

”. Press

ENTER

key to skip extra messages and complete the alignment

process.

6.

If the 1

st

alignment star is a planet, the SynScan hand control will display “

Choose 2

nd

Star

”.

Repeat from Step 2 to complete the alignment process.

1.

While the mount is slewing in alignment process, users may press the

ESC

key to stop the

mount. The hand control screen will display “

MOUNT STOPPED. Press any key…

2.

Press any key and the SynScan hand control will ask the user to select another alignment

star.

3.

Press the

ESC

key again; the LCD screen will display “

Exit Alignment? 1) YES 2) NO

”. Press

key

1

to exit the alignment process; press key

2

to go back to choose an alignment star.

If the telescope has clutches on its axes, user can loosen the clutches to move the mount

manually to point the telescope to the target.