List of contents, Relevant documents, 1 technical data – Richter RV Series Check Valves User Manual
Page 2: 1technical data, Series rv
Series RV
Page 2
9550-070-en
Revision 01
TM 6751
Edition 04/2007
List of Contents
List of Contents ........................................ 2
Relevant documents................................. 2
1 Technical data...................................... 2
Name plate, CE and body markings .......... 3
Tightening torques....................................... 3
Pressure/temperature diagram ................... 3
2 Notes on safety .................................... 4
Intended use................................................ 4
For the customer / operator......................... 4
Improper operation ...................................... 4
3 Safety notes for applications in
potentially explosive areas based on
the Directive 94/9/ EC (ATEX 95) ........ 5
Intended use................................................ 5
4 Safety note for valves, certified to
German Clean Air Act (TA Luft)......... 6
5 Transport and storage......................... 6
Storage ........................................................ 6
Return consignments .................................. 6
6 Installation............................................ 6
Flange caps and gaskets.............................6
Direction of flow and installation position...6
Grounding ....................................................6
Test pressure...............................................6
7 Operation.............................................. 7
Initial commissioning....................................7
7.2
Improper operation and their consequences
7
Shutdown.....................................................7
8 Malfunctions ........................................ 7
9 Maintenance......................................... 7
Dismantling ..................................................7
Assembly .....................................................8
10 Drawing ................................................ 8
Legend .........................................................8
Sectional drawing ........................................8
Relevant documents
Declaration of conformity acc. to the EC Pressure
Equipment Directive 97/23/EC
Form for General Safety Certificate
QM
0912-16-2001_en
1
Technical data
Manufacturer:
Richter Chemie-Technik GmbH
Otto-Schott-Str. 2
D-47906 Kempen
Telephone : +49 (0) 2152 146-0
Fax: +49 (0) 2152 146-190
E-Mail :
Internet:
Designation :
Plug check valve, series RV
Certified to Clean Air Act (TA Luft)
Strength and tightness (P10, P11) of the pressure-
bearing body tested to DIN EN 12266-1.
Gas-tight (P12) in the seat to DIN EN 12266-1,
leak rate A
Face to face: not acc. to DIN
Flange connecting dimensions:
DIN EN 1092-2, type B (ISO 7005-2 Type B) PN 10
Materials
Body material: Ductile cast iron EN-JS 1049 to DIN
EN 1563 (0.7043 DIN 1693)
Lining masterial:
PTFE
Temperature range :
See pressure-temperature diagram in Section 1.3.
Operating pressure :
PN 10
Size in mm :
DN 150, 200
Installation position :
vertical installation
See Section 6.2
Dimensions and individual parts:
See sectional drawings in Section 10
Wear parts :
Shut-off cap, plug stem