2 notes on safety, 1 intended use, 2 for the customer / operator – Richter BVAP/F Series Ball Valves (ASME) User Manual
Page 6: 3 improper operation, Improper operation, Series bva/f, bvap/f, Mer / operator, Ation
Series BVA/F, BVAP/F ,
ASME
9520-085-en_USA
Revision 10
TM 8361
Edition 10/2011
2
Notes on safety
This
operating
manual
contains
fundamental
information which is to be observed during installatio
operation and maintenance.
It must therefore be read before installation and
commissioning!
For valves which are used in potentially explosive
areas, see Section 3.
Installation and operation are to be performed by
qualified staff.
The area of responsibility, authority and supervision of
the staff must be regulated by the customer.
General hazard symbol!
People may be put at risk.
Safety symbol! The valve and its function
may be put at risk if this safety symbol is not
observed.
It is imperative to observe warnings and signs
attached directly to the ball valve and they are to be
kept fully legible.
Failure to heed and follow these notes on
safety may cause damages to persons
and property!
The manufacturer is not responsible for and
hereby disclaims all damages resulting from a
failure to observe adequate safety precautions in
connection with the operation, maintenance and
repair of the valves!
For example, non-observance may involve the
following hazards:
Failure of important functions of the valve/
Risk to people from electric, mechanical and
chemical effects.
Risk to the environment through leaks of hazar
ous substances.
2.1 Intended use
Ball valves are on/off valves.
Richter ball valves of the series BVA/F a
are pressure containing components in accordance
with the Pressure Equipment Directive (PED) for the
passage and shut-off of fluids. The valves are suitable
for vapours, gases and non-boiling liquids of group 1
according to the PED and have a corrosion
plastic lining.
Solids can lead to increased wear, damage to sealing
surfaces or to a reduction in the service life of the
valve.
fundamental
g installation,
allation and
ly explosive
erformed by
upervision of
er.
its function
ymbol is not
and signs
ey are to be
se notes on
to persons
le for and
ing from a
cautions in
enance and
involve the
ve/plant.
hanical and
s of hazard-
and BVAP/F
accordance
PED) for the
are suitable
s of group 1
ion-resistant
ge to sealing
e life of the
The operator must carefully examine in the event of
operating data other than those provided whether the
designs of the valve, accessorie
suitable for the new application (consult the manufa
turer).
2.2 For the customer / operator
When using the valve, it must be ensured that
actuators which are retrofitted are adapted to suit
the valve
hot or cold valve parts are
protected by the customer
against being touched
the ball valve has been properly installed in the
pipe system
the operating conditions stipulated in the data
sheet are not exceeded in continuous operating
mode.
This is not the manufacturer's responsibility.
Loads caused by earthquakes were not allowed for in
the design.
Ball valves at the end of a pipe
must be sealed with a blind flange at the free
connection end and
against unauthorised activation.
Fire protection to DIN EN ISO 10497 is not possible
(plastic lining and plastic components).
2.3 Improper operation
Permitted operation of these valves is limited to the
intended purpose, as shown in
operating instructions.
Under no circumstances must the op
parameters specified on the identification
plate and in the pressure
diagram be exceeded.
Failure to operate the valves within the operating
parameters voids the warranty!
See also improper operation and their consequences
in Section 6.4.
Page 6
examine in the event of
se provided whether the
sories and materials are
on (consult the manufac-
mer / operator
be ensured that
tted are adapted to suit
are
mer
properly installed in the
stipulated in the data
in continuous operating
responsibility.
s were not allowed for in
nd of a pipe (end valve)
a blind flange at the free
d appropriately secured
n.
O 10497 is not possible
ponents).
ation
valves is limited to the
in Section 2.1 of these
nces must the operating
d on the identification
e
pressure-temperature
d.
es within the operating
nty!
and their consequences