TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.

Inspection, testing, and repair of electrical equipment should be performed only by qualifi ed service person-
nel.

• This brewer is heated at all times. Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

• Unplug the brewer when servicing, except when electrical tests are specifi ed.

• Follow recommended service procedures

• Replace all protective shields or safety notices

PROBLEM

Water is not hot

Spitting or excessive steaming

PROBABLE CAUSE

1. Limit Thermostat
CAUTION - Do not eliminate or
bypass limit thermostat/thermal
cut-off. Use only BOM replace-
ment part.
Limit Thermostat - #29329.0001

2. Control Thermostat

3. Tank Heater

1. Lime Build-up
CAUTION - Tank and tank com-
ponents should be delimed
regularly depending on local
water conditions. Excessive min-
eral build-up on stainless steel
surfaces can initiate corrosive
reactions resulting in serious
leaks.

2. Control Thermostat

REMEDY

Refer to Service - Limit Thermo-
stat for testing procedures. See
page 10

Refer to Service - Control Ther-
mostat for testing procedures.
See page 9

Refer to Service - Tank Heater for
testing procedures. See page 10

Inspect the tank assembly for
excessive lime deposits. Delime
as required.

Refer to Service - Control Ther-
mostat for testing procedures.
See page 9