BAL-132





































3)
The power splitter cable has a two-pole

twist lock connector. Align the polarized
pins, insert and twist to lock.


The splitter connects to the Universal AC
power supply, or a 12 Volt DC source.

1) Connect the lamp harness
to the end of the ballast
marked LAMP. Twist the lock
ring to lock in place.
LAMP switch must be set to
off “O”.

2) Connect the power splitter to the
power cable of the ballast. Two
ballasts can operate from one power

splitter cable.

The BAL-132 has two power options:

A) Use external power supply (PWS-152)

to operate on 90-230VAC/12VDC.
IEC power cables (USA/Euro) are
included.

B) Operate on 12VDC. Choose from

accessory cables; Cigarette adapter
cable, Alligator clip cable, twist lock

to XLR battery adapter.

4) Turn on power switch, “I” , on ballast after

power is applied.


In cold temperatures the lamps may require a
few minutes to warm up and come to their full
light output.