MODEL KEFS LIQUID LEVEL FLOAT SWITCH
O-RING REPAIR KIT INSTRUCTIONS.
RK-S-KEFS, O-RING REPAIR KIT
Unscrew Switch Cover and remove old O-Ring. Gently place new O-Ring on Switch Cover, taking care
not to over stretch the o-ring. Make sure o-ring is seated in groove behind threads. Screw Switch Cover back
in place.
Unless the Conduit Connector is removed for some reason, its o-ring should never need to be replaced.
If the need to replace it does arise, simply unscrew the Conduit Connector, remove the old o-ring and replace
it with a new one. Again, take care not to damage the new o-ring when installing, and make sure o-ring is fully
seated into groove behind threads. Reverse disassembly procedure to install.