beautypg.com

2appliance details – Bosch Model GWH 425 User Manual

Page 3

background image

6 720 608 034

Appliance details

3

2

Appliance details

2.1

GWH 425 PN

specifications

(Technical data)

Approved in US/Canada

Capacity
GWH 425 PN: 4.3 GPM

Maximum output
GWH 425 PN: 91 525 Btu/hr

Maximum input
GWH 425 PN: 117 000 Btu/hr

Efficiency in %
Recovery efficiency 78%

Min. Output
GWH 425 PN: 23 906 Btu/hr

Gas Requirement
Gas connection (inches) - ¾” NPT
Inlet gas pressure under maximum operation*
• Propane: 10.5” - 14” water column
• Natural Gas: 5.7” - 14” water column.
* To measure Gas Pressure, see Measuring Gas
Pressure, chapter 3.8.

Venting
• Natural Draft
• Vent diameter (inches) - 5”
• Minimum height (feet) - 6’ with no elbows
• Vertical termination
• Sidewall termination only with AQ4 power vent kit.

Water
• Hot water connection (inches) - ½” NPT
• Cold water connection (inches) - ½” NPT
• Water valve material: Polymer (PPS) (Polypropylene

Sulfid)

• Minimum water flow: 0.5 gallon/minute (1.9 l/m)
• Minimum recommended water pressure: 30 PSI

(2.07 bar)

• Connections:

– Bottom of heater

Dimensions
GWH 425 PN:
• Depth (in): 8.66” (220 mm)
• Width (in): 18.11” (460 mm)
• Height (in): 25.79” (655 mm)
• Weight: 35 pounds (16 kg).

Gas types
Natural Gas.
LP Gas

Safety devices
• Flame failure device (ionization flame rod sensor)
• Pressure relief valve (supplied with heater)
• Over heat prevention (temperature limiter).

Water resistant
IP X4.