beautypg.com

Installing natural gas line, Operating instructions, Assembly instructions (continued) – Blue Rhino Outdoor Natural Gas Barbecue Grill GBC873WNG User Manual

Page 10

background image

GOLD

Outdoor Natural Gas Barbecue Grill Model No. GBC873WNG

Contact 1.800.762.1142 for assistance. Do not return to place of purchase.

Installing Natural Gas Line

Installation should be done by a qualified service person.

CAUTION: If young children are in the area, a locking valve should be
considered.

Connect Natural Gas Line

Before connecting, be sure that there is no debris caught in
the head of the natural gas line, head of the grill natural gas
line or in the head of the burner and burner ports.

Connect grill natural gas line to natural gas line.

Disconnect Natural Gas Line

Before disconnecting make sure the natural gas line valve is “OFF”.

Disconnect grill natural gas line from natural gas line.

Operating Instructions

Checking for Leaks

Burner Connections

1. Make sure the regulator valve and hose connections

are securely fastened to the burner and the gas
line.

If your unit was assembled for you, visually check
the connection between the burner venturi pipe and
orifice. Make sure the burner venturi pipe fits over
the orifice.

WARNING: Failure to inspect this

connection or follow these instructions

could cause a fire or an explosion

which can cause death, serious bodily

injury, or damage to property.

2. Please refer to diagram for proper installation.

(Figure 1 and 2)

3. If the burner pipe does not rest flush to the orifice,

please contact 1.800.762.1142 for assistance.

Tank/Gas Line Connection

1. Make 2-3 oz. of leak solution by mixing one part

liquid dishwashing soap with three parts water.

2. Make sure control knobs are “OFF”. (Figure 3)

3. Turn “ON” natural gas main valve.

4. Spoon leak check solution at all “X” locations

(Figure 4)

a. If any bubbles appear turn natural gas main valve

“OFF”, reconnect and re-test.

b. If you continue to see bubbles after several

attempts, turn natural gas main valve “OFF”
and disconnect natural gas line and contact
1.800.762.1142 for assistance.

c. If no bubbles appear after one minute turn

natural gas main valve “OFF”, wipe away solution
and proceed.

Operating Main Burners

First Use

1. Make sure all labels, packaging and protective films

have been removed from the grill.

2. Remove manufacturing oils before cooking on this

grill for the first time, by operating the grill for at
least 15 minutes on “HIGH” with the lid closed. This
will “heat clean” the internal parts and dissipate
odors.

Figure 1

NG
Connection

NG Valve with
Orifice

Burner
venturi
pipe

Main Burners

Figure 2

Burner
venturi pipe

NG
Connection

NG Valve
with Orifice

Side Burner

Figure 3

Figure 4

Assembly Instructions (continued)

25

Attach Grease Cup and Grease Cup Support