Warning – Bertazzoni X365GGVX (X36 5 00 X) User Manual
Page 2
2
WARNING
Read this instruction booklet before installing and using the appliance.
The manufacturer will not be responsible for any damage to property or to persons caused by
incorrect installation or improper use of the appliance.
The manufacturer reserves the right to make changes to its products when considered necessary and useful,
without affecting the essential safety and operating characteristics.
This appliance has been designed for non-professional, domestic use only.
Warning: do not use this appliance to heat a room.
Warning: do not place any pot or pan on the open oven door. The door is made of glass and it can
break if loaded with a weight.
Warning: this appliance must be used only with base feet properly installed. See installation
instruction for details.
Installation instructions
This appliance shall only be installed by an authorized person. This appliance shall be installed in
accordance with the manufacturer’s installation instructions, IMPORTANT: this appliance must be
installed in accordance with the norms & standards of the country where it will be installed.
The installation of this appliance must conform to local codes and ordinances. In the absence of
local codes, Installations must conforms to American National Standards, National Fuel Gas Code
ANSI Z223.1 – latest edition** or B149.1.
If local codes permit, a flexible metal appliance connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. is recommended for connecting this appliance to the gas
supply line. Do not bend or damage the flexible connector when moving the appliance. The pressure
regulator has ½” female pipe thread. The appropriate fitting must be determined based on the size of
your gas supply line, the flexible metal connector and the shutoff valve.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in
the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than ½ psi (3.5 kPa).
For use with a pressure regulator. The regulator supplied must be used with this appliance; it shall
be properly installed in order to be accessible when appliance is installed in its final location.
The gas appliance pressure regulator must be set for the gas with which the appliance is used.
This appliance can be used with Natural Gas and LP Gas. It is shipped from the factory adjusted for
use with Natural Gas: CONVERSION FIXED ORIFICES ARE LOCATED IN THE LITERATURE PACK
SUPPLIED WITH THE UNIT.
A gas nozzle kit for the change of type of gas are contained inside the package together with the
gas appliance installation kit and instruction booklet.
The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator is 20’’
water column (5 kPa) .
The minimum gas supply pressure for checking the regulator setting shall be at least 1“ w.c. (249 Pa)
above the inlet specified manifold pressure to the appliance (this operating pressure is 4” w.c.
(1.00 kPa) for Natural Gas and 11” w.c. (2.75 kPa for LP Gas).
All opening and holes in the wall and floor, back and under the appliance shall be sealed before
installation of the appliance.
ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the
appliance for the purpose of turning on or shutting off gas to the appliance